ELMAG START STOP AUTOMATIC CONTROLLER AT 206 53347

Sku: T-493786
Discontinued item
Ask a question

Product variants

Sku: Name: SKU manufacturer:
ELMAG START STOP AUTOMATIC CONTROLLER AT 206 53309 T-497961 START STOP AUTOMATIC CONTROLLER AT 206 53309
ELMAG START STOP AUTOMATIC CONTROLLER AT 206 53312 T-500033 START STOP AUTOMATIC CONTROLLER AT 206 53312
ELMAG START STOP AUTOMATIC CONTROLLER AT 206 53362 T-502042 START STOP AUTOMATIC CONTROLLER AT 206 53362
doneStart-Stopp-Automatik AT 206 für Stromerzeuger von 1-44 kVA
done230 Volt - 46 kVA (200A) / 400 Volt - 87 kVA (125A)(for gasoline engines: E-Choke or Auto-Choke required, for diesel engines: Magneto-Stop required, for 400 Volt - 46 kVA (200A) / 400 Volt - 87 kVA (125A))
START STOP AUTOMATIC CONTROLLER AT 206 230 Volt - 46 kVA (200A) / 400 Volt - 87 kVA (125A)
(for petrol engines): E-choke or auto-choke necessary,
for diesel engines: Magneto-stop necessary, with 400 volts devices art. no. 53314 necessary)|Automatic start-stop control AT 206 - The heart of emergency power systems|AT 206 - emergency power and more|AT 206 - start-up ensured by constant control|Status monitoring and alarm display|Emergency power units protect users and operators of technical systems from the consequences of a power failure. They consist of a generator with an electric start system and an AT 206 start-stop automatic controller. For generators with petrol engines, an additional electric choke is required. Diesel-powered generators must have a magneto-stop system. Both systems are available as options or as standard, depending on the model.|The AT 206 automatic control unit turns a power generator into a reliable emergency power system which is always ready to use.
If the mains current fails or the voltage limit is not reached, the power generator is started automatically and takes over the power supply of the connected loads.
When the mains current returns or when the correct mains voltage is restored, the generator is stopped and the automatic controller returns to monitoring status.
If necessary, a self-test of the generator is carried out at regular intervals. The motor and generator functions are
checked. The test run times and intervals are freely programmable.|The control module automatically monitors the mains power supply, the generator and the starter battery. The currently measured values can be displayed on the LCD:
- Current (A)
- Electrical power (kVA)
- Current frequency (Hz)
- Battery voltage (V DC)
- Operating hours (hours)
- Voltage (V AC)|All vital power generator systems are constantly monitored:
A01 engine temperature high / A02 oil pressure low (depending on the generator)/A03 mechanical alarm / A04 generator fault / A05 engine speed high /
A06 engine speed low / A07 generator voltage low / A08 generator voltage high / A09 fuel level low1) / A10 generator
overload / A11 battery voltage low / A12 battery voltage high / A13 false start / E01 remote stop / E02 emergency stop

Product data

Manufacturer:
ELMAG
Condition:
NEW
Sku:
T-493786
SKU manufacturer:
53347
GTIN Code (EAN):
9004853533471
Weight:
0,75 Kg
All information relating to products from ELMAG. Technical and optical modifications of the manufacturer and errors reserved. This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.

Product description

  • Easy-to- read LCD, easy operation with softkeys and LED displays
  • Automatic mode with permanent mains monitoring, continuous readiness for start-up and fully automatic switching mains - generator - mains
  • Integrated contactors electrically and mechanically locked
  • Automatic test runtimes and intervals programmable
  • Visual and acoustic alarm signal
  • Emergency stop button
  • Ideal for wall mounting in
    engine room, energy container or
    any other position
  • AT 206 for 230 volt generators
  • - Models for 230 volt generators with a switching capacity of up to 9, 16, 22 or 46 kVA
  • - Single-phase mains monitoring (standard)
  • AT 206 for 400 volt generators
  • - Models for 400 volt generators with a
    switching capacity up to 18, 31, 42 or 87 kVA
  • - Single-phase mains monitoring (standard)
  • - 3-phase mains monitoring
    available as an option (recommended)
  • TB 125 Vario - klein ganz groß, Notstromaggregate schützen die Benutzer und Betreiber technischer Systeme vor den Folgen eines Stromausfalls. Sie bestehen aus einem Stromerzeuger mit Elektrostart-System und der Start-Stopp-Automatiksteuerung AT 206. Für Stromerzeuger mit Benzinmotor ist zusätzlich ein Elektrochoke erforderlich. Dieselbetriebene Stromerzeuger müssen über ein Magneto-Stopp-System verfügen. Beide Systeme sind optional erhältlich oder je nach Modell serienmäßig.
  • Die Automatiksteuerung AT 206 macht aus einem Stromerzeuger eine verlässliche, stets betriebsbereite Notstromanlage.
    Bei Ausfall des Netzstroms bzw. bei Unterschreitung der eingestellten Spannungsgrenze wird der Stromerzeuger automatisch gestartet und übernimmt die Energieversorgung der angeschlossenen Verbraucher.
    Bei Wiederkehr des Netzstroms bzw. bei Wiedererreichen der korrekten Netzspannung wird der Stromerzeuger gestoppt und die Automatiksteuerung kehrt in den Überwachungsstatus zurück.
    In regelmäßigen Zeitabständen erfolgt bei Bedarf ein Selbsttest des Stromerzeugers. Dabei werden die Motor- und Generatorfunktionen
    geprüft. Die Testlaufzeiten und -intervalle sind frei programmierbar.
  • Das Steuermodul überwacht automatisch das Stromnetz, den Generator und die Startbatterie. Die aktuell gemessenen Werte sind am LCD-Display anzeigbar:
    - Stromstärke (A)
    - Elektrische Leistung (kVA)
    - Stromfrequenz (Hz)
    - Batteriespannung (V DC)
    - Betriebsstunden (hours)
    - Spannung (V AC)
  • Alle betriebswichtigen Systeme des Stromerzeugers werden laufend überwacht:
    A01-Motortemperatur hoch / A02-Öldruck niedrig (Geräteabhängig) / A03-Mechanikalarm / A04-Generatorstörung / A05-Motordrehzahl hoch /
    A06-Motordrehzahl niedrig / A07-Generatorspannung niedrig / A08-Generatorspannung hoch / A09-Kraftstoffstand niedrig1) / A10-Generator
    Überlast / A11-Batteriespannung niedrig / A12-Batteriespannung hoch / A13-Fehlstart / E01-Fernstoppung / E02-Not-Stopp

Additional information

Dimensions (mm):
450x285x170mm
cont. power (230 V) (kVA):
200kVA
Power cont. (400 V) (A):
125A
Max. power (230 V) (kVA):
46kVA
Max. power (400 V) (kVA):
87kVA
Protection type:
IP20