Start-Stopp-Automatik AT 206 für Stromerzeuger von 1-44 kVA
230 Volt - 9 kVA (40A) / 400 Volt - 18kVA (25A)(for gasoline engines: E-Choke or Auto-Choke necessary,for diesel engines: Magneto-Stop necessary,for 400 Volt - 16 kVA (72A))
230 Volt - 9 kVA (40A) / 400 Volt - 18kVA (25A)(for gasoline engines: E-Choke or Auto-Choke necessary,for diesel engines: Magneto-Stop necessary,for 400 Volt - 16 kVA (72A))
START STOP AUTOMATIC CONTROLLER AT 206 230 volts - 9 kVA (40A) / 400 volts - 18 kVA (25A)
(for petrol engines: E-choke or auto-choke necessary,
for diesel engines: Magneto-stop necessary,
with 400 volts devices art. no. 53314 necessary)|Automatic start-stop control AT 206 - The heart of emergency power systems|AT 206 - emergency power and more|AT 206 - start-up ensured by constant control|Status monitoring and alarm display|Emergency power units protect users and operators of technical systems from the consequences of a power failure. They consist of a generator with an electric start system and an AT 206 start-stop automatic controller. For generators with petrol engines, an additional electric choke is required. Diesel-powered generators must have a magneto-stop system. Both systems are available as options or as standard, depending on the model.|The AT 206 automatic control unit turns a power generator into a reliable emergency power system which is always ready to use.
If the mains current fails or the voltage limit is not reached, the power generator is started automatically and takes over the power supply of the connected loads.
When the mains current returns or when the correct mains voltage is restored, the generator is stopped and the automatic controller returns to monitoring status.
If necessary, a self-test of the generator is carried out at regular intervals. The motor and generator functions are
checked. The test run times and intervals are freely programmable.|The control module automatically monitors the mains power supply, the generator and the starter battery. The currently measured values can be displayed on the LCD:
- Current (A)
- Electrical power (kVA)
- Current frequency (Hz)
- Battery voltage (V DC)
- Operating hours (hours)
- Voltage (V AC)|All vital power generator systems are constantly monitored:
A01 engine temperature high / A02 oil pressure low (depending on the generator)/A03 mechanical alarm / A04 generator fault / A05 engine speed high /
A06 engine speed low / A07 generator voltage low / A08 generator voltage high / A09 fuel level low1) / A10 generator
overload / A11 battery voltage low / A12 battery voltage high / A13 false start / E01 remote stop / E02 emergency stop
(for petrol engines: E-choke or auto-choke necessary,
for diesel engines: Magneto-stop necessary,
with 400 volts devices art. no. 53314 necessary)|Automatic start-stop control AT 206 - The heart of emergency power systems|AT 206 - emergency power and more|AT 206 - start-up ensured by constant control|Status monitoring and alarm display|Emergency power units protect users and operators of technical systems from the consequences of a power failure. They consist of a generator with an electric start system and an AT 206 start-stop automatic controller. For generators with petrol engines, an additional electric choke is required. Diesel-powered generators must have a magneto-stop system. Both systems are available as options or as standard, depending on the model.|The AT 206 automatic control unit turns a power generator into a reliable emergency power system which is always ready to use.
If the mains current fails or the voltage limit is not reached, the power generator is started automatically and takes over the power supply of the connected loads.
When the mains current returns or when the correct mains voltage is restored, the generator is stopped and the automatic controller returns to monitoring status.
If necessary, a self-test of the generator is carried out at regular intervals. The motor and generator functions are
checked. The test run times and intervals are freely programmable.|The control module automatically monitors the mains power supply, the generator and the starter battery. The currently measured values can be displayed on the LCD:
- Current (A)
- Electrical power (kVA)
- Current frequency (Hz)
- Battery voltage (V DC)
- Operating hours (hours)
- Voltage (V AC)|All vital power generator systems are constantly monitored:
A01 engine temperature high / A02 oil pressure low (depending on the generator)/A03 mechanical alarm / A04 generator fault / A05 engine speed high /
A06 engine speed low / A07 generator voltage low / A08 generator voltage high / A09 fuel level low1) / A10 generator
overload / A11 battery voltage low / A12 battery voltage high / A13 false start / E01 remote stop / E02 emergency stop
Product data
Manufacturer:
ELMAG
Condition:
NEW
Sku:
T-497961
SKU manufacturer:
53309
GTIN Code (EAN):
9004853533099
Weight:
2,50 Kg
All information relating to products from ELMAG. Technical and optical modifications of the manufacturer and errors reserved.
Product description
- Easy-to- read LCD, easy operation with softkeys and LED displays
- Automatic mode with permanent mains monitoring, continuous readiness for start-up and fully automatic switching mains - generator - mains
- Integrated contactors electrically and mechanically locked
- Automatic test runtimes and intervals programmable
- Visual and acoustic alarm signal
- Emergency stop button
- Ideal for wall mounting in
engine room, energy container or
any other position - AT 206 for 230 volt generators
- - Models for 230 volt generators with a switching capacity of up to 9, 16, 22 or 46 kVA
- - Single-phase mains monitoring (standard)
- AT 206 for 400 volt generators
- - Models for 400 volt generators with a
switching capacity up to 18, 31, 42 or 87 kVA - - Single-phase mains monitoring (standard)
- - 3-phase mains monitoring
available as an option (recommended)
- TB 125 Vario - klein ganz groß, Notstromaggregate schützen die Benutzer und Betreiber technischer Systeme vor den Folgen eines Stromausfalls. Sie bestehen aus einem Stromerzeuger mit Elektrostart-System und der Start-Stopp-Automatiksteuerung AT 206. Für Stromerzeuger mit Benzinmotor ist zusätzlich ein Elektrochoke erforderlich. Dieselbetriebene Stromerzeuger müssen über ein Magneto-Stopp-System verfügen. Beide Systeme sind optional erhältlich oder je nach Modell serienmäßig.
- Die Automatiksteuerung AT 206 macht aus einem Stromerzeuger eine verlässliche, stets betriebsbereite Notstromanlage.
Bei Ausfall des Netzstroms bzw. bei Unterschreitung der eingestellten Spannungsgrenze wird der Stromerzeuger automatisch gestartet und übernimmt die Energieversorgung der angeschlossenen Verbraucher.
Bei Wiederkehr des Netzstroms bzw. bei Wiedererreichen der korrekten Netzspannung wird der Stromerzeuger gestoppt und die Automatiksteuerung kehrt in den Überwachungsstatus zurück.
In regelmäßigen Zeitabständen erfolgt bei Bedarf ein Selbsttest des Stromerzeugers. Dabei werden die Motor- und Generatorfunktionen
geprüft. Die Testlaufzeiten und -intervalle sind frei programmierbar. - Das Steuermodul überwacht automatisch das Stromnetz, den Generator und die Startbatterie. Die aktuell gemessenen Werte sind am LCD-Display anzeigbar:
- Stromstärke (A)
- Elektrische Leistung (kVA)
- Stromfrequenz (Hz)
- Batteriespannung (V DC)
- Betriebsstunden (hours)
- Spannung (V AC) - Alle betriebswichtigen Systeme des Stromerzeugers werden laufend überwacht:
A01-Motortemperatur hoch / A02-Öldruck niedrig (Geräteabhängig) / A03-Mechanikalarm / A04-Generatorstörung / A05-Motordrehzahl hoch /
A06-Motordrehzahl niedrig / A07-Generatorspannung niedrig / A08-Generatorspannung hoch / A09-Kraftstoffstand niedrig1) / A10-Generator
Überlast / A11-Batteriespannung niedrig / A12-Batteriespannung hoch / A13-Fehlstart / E01-Fernstoppung / E02-Not-Stopp
Additional information
Dimensions (mm):
450x285x170mm
Power cont. (230 V) (A):
40A
Power cont. (400 V) (A):
25A
Max. power (230 V) (kVA):
9kVA
Max. power (400 V) (kVA):
18kVA
Protection type:
IP20
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-16%
Extension for leggings WELDAS 44-7114EXT
58168
€13.40
(€7.98 / Piece)
€16.01 MSRP
-25%
Nozzle set for model 162
32031
€20.25
€27.02 MSRP
-11%
Stop switch On/Off switch for HONDA engine
9503773
€74.03
-30%
Collet set MK 4 / M16
82782
€252.43
€361.00 MSRP
-24%
CR-NI welding wire (1.4316)
54186
€380.29
€502.01 MSRP
-22%
Diamond disc 350 mm
61540
€109.20
€140.00 MSRP
-4%
Polierscheibe
9000341
€16.09
-29%
Lever support No. 32
9808617
€76.93
€107.98 MSRP
-27%
Lever complete (no. 11-15)
9801976
€34.44
€47.02 MSRP
-28%
Perspex drill chuck protection compl.
9106232
€49.20
€67.98 MSRP
-7%
Zentralschmiereinheit
9802855
€198.95
-14%
Motherboard for inverter S 1600
9505464
€660.59
-18%
Welding electrodes for cutting & grooving MT-Fug
55682
€60.55
€73.99 MSRP
-6%
Drehgeber für Sägearm Höheneinstellung
9706179
€266.38
-15%
Gummipuffer bei Führungsholm
9603031
€35.62
ELMAG START STOP AUTOMATIC CONTROLLER AT 206 53309
53309
ELMAG Entwicklungs- und Handels GmbH
Power Generators
- Easy-to- read LCD, easy operation with softkeys and LED displays
- Automatic mode with permanent mains monitoring, continuous readiness for start-up and fully automatic switching mains - generator - mains
- Integrated contactors electrically and mechanically locked
- Automatic test runtimes and intervals programmable
- Visual and acoustic alarm signal
- Emergency stop button
- Ideal for wall mounting in
engine room, energy container or
any other position - AT 206 for 230 volt generators
- - Models for 230 volt generators with a switching capacity of up to 9, 16, 22 or 46 kVA
- - Single-phase mains monitoring (standard)
- AT 206 for 400 volt generators
- - Models for 400 volt generators with a
switching capacity up to 18, 31, 42 or 87 kVA - - Single-phase mains monitoring (standard)
- - 3-phase mains monitoring
available as an option (recommended)