STATIC VALUES | HARDWOOD CHARACTERISTIC VALUES EN 1995:2014 SHEAR CONNECTION WITH CROSSED CONNECTORS RIGHT-ANGLE JOINT - MAIN BEAM/SECONDARY BEAM d1 eq. d1 L [mm] [mm] [mm] 6 6 140 180 S g HT(1) S g NT (1) [mm] [mm] 40 75 70 75 BHT min HHT min = hNT min bNT min [kN] 65 80 [mm] 110 140 7 6 6 8 8 220 260 200 240 95 115 75 105 95 115 95 105 95 110 90 100 170 195 155 185 9 8 8 280 320 125 145 125 145 115 130 210 240 R1 V,k(1) no. pairs [mm] R2 V,k(2) R3 V,k(2) m(3) [mm] [kN] [kN] [kN] withdrawal (4) instability tension 57 1 7,7 14,0 25,5 87 2 14,4 26,1 47,5 117 3 20,8 37,8 68,7 57 1 14,4 14,0 25,5 87 2 26,9 26,1 47,5 117 3 38,9 37,8 68,4 57 1 18,3 14,0 25,5 87 2 34,1 26,1 47,5 117 3 49,3 37,8 68,4 57 1 22,1 14,0 25,5 87 2 41,3 26,1 47,5 117 3 59,7 37,8 68,4 76 1 19,2 45,5 45,3 116 2 35,9 85,0 84,4 156 3 51,9 122,9 121,6 76 1 26,9 45,5 45,3 116 2 50,2 85,0 84,4 156 3 72,7 122,9 121,6 76 1 32,0 45,5 45,3 116 2 59,8 85,0 84,4 156 3 86,5 122,9 121,6 76 1 37,2 45,5 45,3 116 2 69,4 85,0 84,4 156 3 100,4 122,9 121,6 62 65 79 94 80 87 101 115 NOTES: GENERAL PRINCIPLES: (1) The values given are calculated considering a distance a 1,CG ≥ 5d. In some cases the asymmetrical laying of connectors is needed (Sg HT ≠ Sg NT ). (2) The compression design strength of the connector is the lower between • Characteristic values comply with the EN 1995:2014 standard in accordance with ETA-11/0030. the withdrawal-side design strength (R 1 V,d), the instability design strength (R 2 V,d) and the tensile design strength (R3 V,d). RV,d = min R1V,k kmod γM R2V,k γM1 R3V,k γM2 • For the mechanical resistance values and the geometry of the screws, reference was made to ETA-11/0030. • For the calculation process a mass density equal to ρk = 550 kg/m3 has been considered for hardwood (oak) elements. • Dimensioning and verification of the timber elements must be carried out separately. The coefficients γM and kmod should be taken according to the current regulations used for the calculation. (3) The assembly height (m) applies in the event of symmetrical installation of the flush connectors (Sg HT = Sg NT ) above the elements. (4) The thread axial resistance to withdrawal has been evaluated considering an effective thread length equal to Sg. The connectors must be inserted at 45° with respect to the shear plane. STRUCTURES | VGZ HARDWOOD | 183
369 Sidor | Gäller till 04/2024 | Previous page | Nästa sida
Välj ditt språk
Juridiska frågor
Tillverkaren ansvarar exklusivt för innehållet, priset och artikeldetaljerna för produkterna och erbjudanden som presenteras i katalogerna. Med förbehåll för tekniska och optiska ändringar av tillverkaren och undantag för fel.
Formulär för specialprodukter
ToolTeam® upphandlingstjänst
Letar du efter produkter som visas i katalogen men inte kan köpas direkt online?Vår upphandlingstjänst kommer med glädje att ge dig ett icke-bindande och individuellt erbjudande.