Pneumax - Hauptkatalog Pagina 521
Commercieel klantenaanbod**Beste verkopers van Pneumax GmbH
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Solenoid valves manifold Series 2500 "OPTYMA-T" Multipolar connections Please note: Optyma 32-T solenoid valve manifolds manage up to 32 signals. If the manifold uses more than 24 signals the I/O module will manage only the remainder. Connections that are not managing useful signals will remain unconnected. 1 2 3 4 ... 8 9 10 11 21 22 23 24 37 poles Connettor Multi-pole 12 13 14 15 connector pin 2 3 4 ... 21 22 23 24 29 30 31 32 Multi-pole connector pin Not connected Attention: Signal Not connected GND Connected Through line Connected B) Control via fieldbus: With this kind of control the I/O module can only be used as an output. Pin 1 of each connector is not connected. The output voltage will be 0.7V lower than that applied to Pin 4 of the connector. The maximum output current for each output is 100mA. The correspondence between control byte and each single output depends on how many electrical signals are used by the manifold and by the relative position of the I/O module. 3 1 1 2-3 4-5 6 8 9 10 11 7 Attention: Output only Attention: Only one more I/O module can be added. 4 PIN DESCRIPTION 1 NOT CONNECTED 4 SIGNAL 3 GND 12 13 14 15 Serial node Outlet Pin Module 1 1 2-3 4-5 6 8 9 10 11 7 12 13 14 15 Serial node Outlet Pin 16 17 18 19 20 21 22 23 2 3 4 ... 25 26 27 28 29 30 31 32 Attention: Output only Not connected Serial node Outlet Pin Attention: Signal Not connected GND Connected Please note: I/O modules don’t allow to connect any additional valves manifold after them. 1 2-3 4-5 6 Input Module Attention: No more additions are possible Module 1 Module 2 1 Serial node Outlet Pin Attention: Output only 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Attention: Output only Attention: No more additions are possible Modulo 1 Modulo 2 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 501 Air distributiOn 1 37 poles Connettor 1
1106 Pagina’s | Geldig tot 06/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
