Pneumax - Hauptkatalog Pagina 520
Commercieel klantenaanbod**Beste verkopers van Pneumax GmbH
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Solenoid valves manifold Series 2500 "OPTYMA-T" Multipolar connections CORRESPONDENCE BETWEEN MULTI-POLE SIGNAL AND CONNECTOR PIN 13 PIN 12 PIN 11 PIN 10 PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1 PIN 18 PIN 19 PIN 25 PIN 24 PIN 23 PIN 22 PIN 21 PIN 20 PIN 19 PIN 18 PIN 17 PIN 16 PIN 15 PIN 14 1 - 22 = SIGNALS 23 - 24 = GND 25 = THROUGH LINE PIN 37 PIN 36 PIN 35 PIN 34 PIN 33 PIN 32 PIN 31 PIN 30 PIN 29 PIN 28 PIN 27 PIN 26 PIN 25 PIN 24 PIN 23 PIN 22 PIN 21 PIN 20 1 - 32 = SIGNALS 33 - 35 = GND 36 - 37 = THROUGH LINE 1 3 SUB-D TYPE 25 POLE MALE CONNECTOR PIN 17 PIN 16 PIN 15 PIN 14 PIN 13 PIN 12 PIN 11 PIN 10 PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1 SUB-D TYPE 37 POLE MALE CONNECTOR 1 4 PIN DESCRIPTION 1 THROUGH LINE 4 SIGNAL 3 GND Air distributiOn Connection modes: The I/O module changes it is operation depending on the way the manifold is controlled. There are two possible modes: A) Control via multi-pole connection B) Control via fieldbus In order to use the I/O module, the correct right hand endplate with 25 pole female outlet connector must be used. (Code 2540.03.25P). A) Control via multi-pole : M8 connector used as Input: M8 connector used as Output: Attention: Voltage applied to each connector is passed to multi-pole connector pin. Output voltage will the same as is applied at the multi-pole connector pin. The maximum output current depends upon the power unit used, but we recommend no more than 250mA. Attention: Since every cable has a degree of resistance, there will always be a voltage drop depending on the cable’s length, sectional area and the current. 3 1 4 1 2-3 4-5 6 PIN DESCRIPTION 1 THROUGH LINE 4 SIGNAL 3 GND 8 9 10 11 7 Attention: Only one more I/O module can be added. Multi-pole connector pin 1 2-3 4-5 6 37 poles Connector 12 13 14 15 Module 1 8 9 10 11 7 16 17 18 19 Attention: No more additions are possible Multi-pole connector pin 12 13 14 15 20 21 22 23 Module 1 Module 2 Attention : Optyma 32-T solenoid valve manifolds permit up to 22 electrical signals that are not used by manifolds to be made available: these signals can be managed by another manifold and / or by I/O modules. The I/O module will manage these unused signals. Connections that are not managing useful signals will remain unconnected. 22 Signals : 1 37 poles Connettor Multi-pole connector pin 2 3 4-5 1 2-3 4-5 6 6 7-8 9-10 11 12 8 9 10 11 13 14 15 16 16 17 18 19 21 22 23 24 17 18 19 20 12 13 14 15 25 26 27 Maximum 22 Signals Outlet signals from manifold Please note: this example considers a 37 pin multi-pole connector. The same configuration managed by a 25 pin multi-pole connector will stop at number 22 of multi-pole connector and at number 17 of the manifold. 22 17 1 | 500 7 Not Connected 20 21 22 Module 1 Module 2 Attention: Signal Not connected GND Connected Through line Connected Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice
1106 Pagina’s | Geldig tot 06/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
