fischer Rögzítőrendszerek főkatalógusa Pagina 349
Commercieel klantenaanbod**Beste verkopers van Fischer
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Stand-off installation TherMax 8/10 · Frame fixings / Stand-off installation Loads Stand-off installation TherMax 8 and 10 Recommended loads¹) of a single anchor in concrete and masonry. Type TherMax 8 TherMax 10 Supplied type of plug for the anchorage in the base material UX 10 x 60 UX 12 x 70 Recommended tensile loads in the respective base material Nrec²) Concrete³) 4) ≥ C20/25 [kN] 1.00 1.00 Solid brick³)4) ≥ Mz 12 [kN] 0.50 0.70 Perforated sand-lime brick³)4) ≥ KSL 12 [kN] 0.60 0.80 Vertically perforated brick4) ≥ Hlz 12 [kN] 0.20 0.30 Aerated concrete³)4) ≥ AAC 4 [kN] 0.40 0.60 [kN] 0.15 0.20 Recommended shear load Vrec , valid für all above mentioned base materials for the stated insulation thickness External Thermal Insulation Composite System5) ≤ 240 mm ¹) Required safety factors are considered. ²) The drilling method is to be adapted to the building material used. As different joint qualities are possible, the given values only apply for installation in the brick. ³) The given recommended tensile loads apply for fastenings with metric screws. When using chipboard screws with diameter 6.0 mm they have to be reduced to 0.35 kN. 4) The given recommended tensile loads apply for fastenings with metric screws. When using a SX 5-plug chipboard screws with diameter 4.5 - 5.5 mm they have to be reduced to 0.1 kN. 5) Values are valid for an ETICS made from PS- respectively PU-rigid foam panels. Thickness of rendering minimum 6 mm. 5 Loads Stand-off installation TherMax 8 and 10 Recommended shear loads¹) for a single anchor. Type UX 10 + TherMax 8³) UX 12 + TherMax 10³) 0.15 0.20 Recommended shear loads Vrec¹) External thermal insulation composite system²) ≤ 240 mm [kN] ¹) Required safety factors are considered. ²) Values are valid for an ETICS made from PS- respectively PU-rigid foam panels. Thickness of rendering minimum 6 mm. ³) In wood installation without plug. Loads Stand-off installation TherMax 8 and 10 Recommended tensile loads¹) for a single anchor in wood. Type TherMax 8 TherMax 10 Recommended tensile loads in the respective base material Nrec²) Beech ≥ D35 [kN] 1.00³) 1.005) Spruce ≥ C24 [kN] 1.004) 1.005) ¹) Required safety factors are considered. ²) Installation without UX-plug. Edge distances and spacings following Eurocode 5. ³) Pre-drilled wood with diameter 6 mm. 4) Pre-drilled wood with diameter 5 mm. 5) Pre-drilled wood with diameter 7 mm. 349
684 Pagina’s | Geldig tot 12/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.