Rothoblaas - X-RAD Pagina 72
Commercieel klantenaanbod**Beste verkopers van RothoBlaas Deutschland
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
X-ONE X-PLATE X-SEAL ACOUSTIC PERFORMANCE With X-RAD the structural nodes are concentrated in single and distinct points. As regards the acoustics a targeted and calibrated study was carried out within the Flanksound Project on this new building concept in order to achieve the acoustic characterisation of the structural nodes created with X-RAD. Rothoblaas has therefore supported research aimed at measuring the vibration reduction index Kij for a variety of joints between the CLT panels, with the dual objective of providing experimental data specific to acoustic design of buildings in CLT and contributing to development of the calculation methods. Vibration reduction index measurements were performed in accordance with EN ISO 10848. For more information and details on the design and measurement methods, see “Catalogues / Soundproofing“ section in www.rothoblaas.com website. X-SEAL avoids direct acoustic transmission through the air caused by the “emptying” of the mass of the node due to the 45° cut on the CLT panel. SUMMARY OF THE CONFIGURATIONS TESTED WITHIN THE FLANKSOUND PROJECT X-PLATE TOP X X-PLATE BASE O X-PLATE MID O CONSTRUCTION SEALING XYLOFON ALADIN STRIPE TITAN SILENT 45 ACOUSTIC SOLUTION X-PLATE BASE X X-PLATE TOP T X-PLATE BASE T DETAIL FASTENING SYSTEM - - - - - - - - 46 - - 47 - - - - - - 48 - - - - - - 49 - - - - - 50 - - - - - 51 - - - - - 52 - - - - - - - - - - - - - - KEY Data estimated from the experimental measurements FOR MORE INFORMATION A. Speranza, L. Barbaresi, F. Morandi, “Experimental analysis of flanking transmission of different connection systems for CLT panels“ in Proceedings of the World Conference on Timber Engineering 2016, Vienna, August 2016. L. Barbaresi, F. Morandi, M. Garai, A. Speranza, “Experimental measurements of flanking transmission in CLT structures“ in Proceedings of the International Congress on Acoustics 2016, Buenos Aires, September 2016. L. Barbaresi, F. Morandi, M. Garai, A. Speranza, “Experimental analysis of flanking transmission in CLT structures“ of Meetings on Acoustics (POMA), a serial publication of the Acoustical Society of America - POMA-D-17-00015. 70 X-SEAL - - - - - - - - -
84 Pagina’s | Geldig tot 04/2024 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
