Rothoblaas - X-RAD Page 50
Offre client commercial**Meilleures ventes de RothoBlaas Deutschland
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
X-ONE X-PLATE X-SEAL STRUCTURAL ENGINEERING The aim of this section is to provide the resistance specifications for X-PLATE connection plates. The plates, of varying thickness according to the type, are all made of S355JR steel, CE marked according to EN1090 in EXC2 execution class. Each plate has been designed and verified by applying the maximum stresses transmitted by the X-ONE connector, according to three classes of strengths (1): 1. OVERALL STRENGTHS OF THE PLATE (with FEM analysis): shear; pure traction; pure compression; buckling stress or flexural stress. 2. LOCAL STRENGTHS: shear strength of the bolt (EN 1993-1-8 §3.6.1); bearing strength of the plate (EN 1993-1-8 §3.6.1); block tearing strength of the plate (EN 1993-1-8 §8.10.2); strength of the welds. 3. FASTENING STRENGTH ON THE FOUNDATION SUPPORT X-PLATE BASE PLATES The XPLATE BASE plates can be used under the following conditions: use of vinyl ester chemical anchor and 20 mm diameter threaded rod - steel strength grade 8.8 minimum strength class for C25/30 concrete X-PLATE BMINI and BMAXI plates fully restore the resistance of the X-ONE connector. X-PLATE BMINIL/R and BMAXIL/R plates partially restore the resistance of the X-ONE connector. This aspect is illustrated by the resistance domains shown below (2). RESISTANCE DOMAINS OF X-PLATE PLATES COMPARED TO THE RESISTANCE DOMAIN OF THE X-ONE CONNECTOR -250 -200 -150 -100 -50 -325 -275 -225 -175 -125 -75 -25 0 25 75 125 175 225 275 325 50 100 150 200 250 300 X-ONE X-PLATE BMINI local strengths X-PLATE BMINI overall strengths X-PLATE BMINI foundation fastening strength (uncracked concrete hef = 200) X-PLATE BMINI foundation fastening strength (cracked concrete hef = 200) X-PLATE BMINI - Design resistance domain NOTE: (1) The full report on structural design of the X-PLATE plates can be downloaded from www.rothoblaas.com or from the MyProject software. (2) The domains are shown according to the reference system for the X-ONE connector. To refer to the reference system for the X-PLATE plates, by applying forces on the X-PLATE plates that are equal and opposite to those applied on the X-ONE connector, these domains must be mirrored with respect to the bisector of the first quadrant. 48 X-PLATE
84 Pages | Valable jusqu’au 04/2024 | Page précédente | Page suivante
Choisissez votre langue
Probleme juridique
Le fabricant est exclusivement responsable du contenu, des prix et des détails des articles et des offres présentés dans les catalogues. Sous réserve de modifications techniques et optiques du fabricant et sous réserve d’erreurs.
Formulaire de demande de produits spéciaux
Le service d’approvisionnement ToolTeam®
Vous recherchez des produits qui figurent dans le catalogue mais ne peuvent pas être achetés directement en ligne ?Notre service d’approvisionnement se fera un plaisir de vous faire une offre individuelle et sans engagement.