Eurotec catalogue fastening technology Page 297
Commercial customer offer**Top sellers from Eurotec
Wood construction screws Dimensions d1 x L [mm] dk AD ET [mm] [mm] [mm] Extraction resistance Head pull-through resistance Fax,90,Rk [kN] Fax,head,Rk [kN] Wood / wood shearing Fla,Rk [kN] α= 0° Fla,Rk [kN] α=90° Steel / wood shearing Fla,Rk [kN] Fla,Rk [kN] αAD= 0° αAD= 90° αET= 90° αET= 0° t [mm] Fla,Rk [kN] Fla,Rk [kN] α= 0° α= 90° 6,0 x 60 12,0 24 36 2,46 1,73 1,71 2 2,26 6,0 x 70 12,0 28 42 2,87 1,73 1,82 2 2,36 6,0 x 80 12,0 32 48 3,28 1,73 1,93 2 2,46 6,0 x 90 12,0 36 54 3,69 1,73 2,05 2 2,57 6,0 x 100 12,0 40 60 4,10 1,73 2,07 2 2,67 6,0 x 110 12,0 40 70 4,79 1,73 2,07 2 2,84 6,0 x 120 12,0 50 70 4,79 1,73 2,07 2 2,84 6,0 x 130 12,0 60 70 4,79 1,73 2,07 2 2,84 6,0 x 140 12,0 70 70 4,79 1,73 2,07 2 2,84 6,0 x 150 12,0 80 70 4,79 1,73 2,07 2 2,84 6,0 x 160 12,0 90 70 4,79 1,73 2,07 2 2,84 6,0 x 180 12,0 110 70 4,79 1,73 2,07 2 2,84 6,0 x 200 12,0 130 70 4,79 1,73 2,07 2 2,84 6,0 x 220 12,0 150 70 4,79 1,73 2,07 2 2,84 6,0 x 240 12,0 170 70 4,79 1,73 2,07 2 2,84 6,0 x 260 12,0 190 70 4,79 1,73 2,07 2 2,84 6,0 x 280 12,0 210 70 4,79 1,73 2,07 2 2,84 6,0 x 300 12,0 230 70 4,79 1,73 2,07 2 Calculation according to ETA-11/0024. Wood density ρk= 350 kg/m³. All mechanical values provided should be viewed as subject to the assumptions that have been made and represent example calculations. All values are calculated minimum values and are subject to typographical and printing errors. a) The characteristic values of the load-bearing capacity Rk cannot be treated as equivalent to the max. possible load (the max. force). Characteristic values of the load-bearing capacity Rk should be reduced to dimensioning values Rd with regard to the usage class and class of the load duration: Rd= Rk · kmod / γM. The dimensioning values of the load-bearing capacity Rd should be contrasted with the dimensioning values of the loads (Rd ≥ Ed). 2,84 Example: Characteristic value for constant load (dead weight) Gk= 2,00 kN and variable load (e. g. snow load) Qk= 3,00 kN. kmod= 0,9. γM= 1,3. → Dimensioning value of the load Ed= 2,00 · 1,35 + 3,00 · 1,5= 7,20 kN. The load-bearing capacity of the joint is therefore considered to have been demonstrated if Rd ≥ Ed. → min Rk= Rd · γM / kmod i.e. the characteristic minimum value is calculated based on: min Rk= Rd · γM / kmod → Rk= 7,20 kN · 1,3/0,9= 10,40 kN → comparison with table values. Please note: These are planning aids. Projects must only be calculated by authorised persons. 297
444 Pages | Valid until 12/2024 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
