Upat Fastening Technology - Main Catalog Page 71
Commercial customer offer**Top sellers from Upat
Frame fixing URDL Load table Permissible loads1)2) of a single anchor as part of a multiple fixing of non-structural systems For the design, the entire assessment ETA-17/0811 must be considered. Type Anchor diameter Anchoring depth URDL 8 URDL10 d0 [mm] 8 10 hef [mm] 70 70 [kN] 1.39 1.79 Anchoring in concrete ≥ C16/20 Permissible tensile load Nperm Permissible shear load Vperm zp [kN] 3.2 4.4 Permissible shear load Vperm R [kN] 4.51 6.17 Minimum member thickness hmin [mm] 140 140 ccr,N [mm] 105 105 Characteristic edge distance Characteristic spacing distance a bzw. scr,N [mm] 75 90 Minimum spacing distance smin [mm] 90 100 Minimum edge distance cmin [mm] 90 100 Mz [kN] 0,86 - 1,14 0,57 - 1,43 KS [kN] 1.57 1.71 HLz [kN] 0,09 - 0,26 0.09 KSL [kN] 1.43 1.57 Permissible load in solid brick Permissible load Fperm3) in solid sand-lime brick Permissible load Fperm3)4) in perforated brick Permissible load Fperm3) in perforated sand-lime brick Minimum member thickness hmin [mm] 110 - 370 110 - 370 Minimum edge distance (single anchor) cmin [mm] 120 - 185 120 - 185 Minimum spacing distance (anchor group) vertical to the edge s1min [mm] 240 - 370 240 - 370 Minimum spacing distance (anchor group) parallel to the edge s2min [mm] 480 - 740 480 - 740 Minimum edge distance (anchor group) cmin [mm] 75 - 125 75 - 125 Permissible load Fperm3) in aerated concrete ACC [kN] 0.1 0.17 Minimum member thickness Anchoring in aerated concrete hmin [mm] 240 240 Minimum edge distance (single anchor) cmin [mm] 120 120 Minimum spacing distance (anchor group) vertical to the edge s1min [mm] 240 240 Minimum spacing distance (anchor group) parallel to the edge s2min [mm] 480 480 Minimum edge distance (anchor group) cmin [mm] 120 120 Frame fixings Anchoring in masonry The partial safety factors for resistance regulated in the assessment, as well as a partial safety factor for action of γL = 1.4, are taken into account. Valid for temperatures in the anchoring base up to +50 °C (or temporarily up to +80 °C). For long-term temperatures up to +30 °C, higher permissible loads are possible. 3) Valid for tensile, shear, and oblique pull at any angle. For combinations of tensile and shear loads as well as bending moments, see the assessment. 4) Refers to the stones of the respective category regulated in the approval, the highest permissible load, and the installation instructions, which must be evaluated depending on the stone properties. 1) 2) 71
108 Pages | Valid until 12/2026 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.