Upat Fastening Technology - Main Catalog Page 68
Commercial customer offer**
Show products
Top sellers from Upat
539948
€5.37
(€0.64 / Piece)
542955
€5.50
539949
€5.42
(€0.65 / Piece)
520256
€8.03
542947
€8.03
(€0.10 / Piece)
539951
€7.98
(€0.95 / Piece)
000856
€12.77
041913
€13.91
(€0.33 / Piece)
041915
€13.69
(€0.81 / Piece)
541305
€14.33
(€0.34 / Piece)
View all Upat products
Frame fixing URD Load table Permissible loads1)2) of a single anchor as part of a multiple fixing of non-structural systems For the design, the entire assessment ETA-17/0811 must be considered. Type Anchor diameter URD 8 URD 10 d0 [mm] 8 10 hef [mm] 50 50 [kN] 0.99 1.79 Permissible shear load Vperm zp [kN] 4.2 5.98 Permissible shear load Vperm Anchoring depth Anchoring in concrete ≥ C12/15 Permissible tensile load Nperm R [kN] 3.93 5.98 Minimum member thickness hmin [mm] 100 100 Characteristic edge distance ccr,N [mm] 85 140 100 100 Characteristic spacing distance a resp. scr,N [mm] Minimum spacing distance smin [mm] 100 70 At an edge distance c≥ [mm] 85 210 Minimum edge distance cmin [mm] 85 85 At a spacing distance s≥ [mm] 100 100 Permissible load in solid brick Mz [kN] 0,86 1,43 Permissible load Fperm3) in solid sand-lime brick KS [kN] 0.86 1,43 Permissible load Fperm3) in lightweight concrete solid brick Vbl [kN] 0.71 0,86 Permissible load Fperm3) in normal concrete solid brick Vbn [kN] 0,71 1,29 Permissible load Fperm3)4) in perforated brick HLz [kN] 0,34 0,86 Permissible load Fperm3) in perforated sand-lime brick KSL [kN] 0,11 0,43 Permissible load Fperm3)4) in hollow lightweight concrete block Hbl [kN] 0,71 0,71 Permissible load Fperm3) in hollow block lightweight concrete Hbn Hbn [kN] 0,71 Permissible load Fperm3) in thermal insulation block WDB WDB [kN] 0,43 Minimum member thickness Frame fixings Anchoring in masonry hmin [mm] 100 100 Minimum spacing distance (single anchor) amin [mm] 250 250 Minimum edge distance (single anchor) cmin [mm] 100 100 Minimum spacing distance (anchor group) smin [mm] 100 100 Minimum edge distance (anchor group) cmin [mm] 100 100 PB ≥ 2 N/mm2 [kN] Anchoring in aerated concrete Permissible load Fperm3) in aerated concrete Minimum component thickness 0.3 hmin [mm] 100 Minimum spacing distance (single anchor) amin [mm] 250 Minimum edge distance (single anchor) cmin [mm] 100 Minimum spacing distance (anchor group) smin [mm] 400 Minimum edge distance (anchor group) cmin [mm] 100 The partial safety factors of resistance regulated in the assessment, as well as a partial safety factor for action of γL = 1.4, are taken into account. For example, a single anchor is defined as an anchor with a minimum spacing distance "a" according to the ETA. 2) Valid for temperatures in the anchoring base up to +50 °C (or temporarily up to +80 °C). For long-term temperatures up to +30 °C, higher permissible loads are possible. 3) Valid for tensile load, shear load, and oblique pull at any angle. For combinations of tensile and shear loads as well as bending moments, see the assessment. 4) Drilling method: rotary drilling. 1) 68
108 Pages | Valid until 12/2026 | Previous page | Next page
Choose your language
Legal issues
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)
