Upat Fastening Technology - Main Catalog Page 57

Commercial customer offer**
Page 56Upat Fastening Technology - Main Catalog Page 57
Show products
search
keyboard_arrow_up
/ 108

Top sellers from Upat

542582
€49.12
(€2.34 / Piece)
4 Variants
541303
€48.36
(€1.15 / Piece)
8 Variants
535295
€47.44
(€1.13 / Piece)
7 Variants
547605
€48.66
(€1.16 / Piece)
27 Variants
508992
€44.08
(€1.05 / Piece)
17 Variants
547295
€50.33
(€1.20 / Piece)
6 Variants
547282
€48.74
(€2.32 / Piece)
18 Variants
547257
€44.08
(€2.10 / Piece)
9 Variants
547265
€44.50
(€2.12 / Piece)
4 Variants
546949
€50.21
(€5.98 / Piece)
17 Variants
546962
€47.39
(€5.64 / Piece)
14 Variants
543366
€45.62
(€1.09 / Piece)
9 Variants
546908
€50.29
(€5.99 / Piece)
21 Variants
543346
€44.79
(€1.07 / Piece)
8 Variants
007860
€5.20
(€0.62 / Piece)
23 Variants
539948
€5.37
(€0.64 / Piece)
542955
€5.50
542785
€5.42
(€0.13 / Piece)
8 Variants
539949
€5.42
(€0.65 / Piece)
551766
€7.47
5 Variants
518878
€7.94
(€0.09 / Piece)
8 Variants
518882
€7.94
(€0.09 / Piece)
5 Variants
542947
€8.03
(€0.10 / Piece)
542586
€7.52
(€0.18 / Piece)
4 Variants
539951
€7.98
(€0.95 / Piece)
535287
€12.98
(€0.77 / Piece)
11 Variants
522464
€12.90
(€1.54 / Piece)
13 Variants
043665
€14.20
(€1.69 / Piece)
3 Variants
509056
€13.86
(€0.33 / Piece)
6 Variants
007846
€13.69
(€1.63 / Piece)
25 Variants
509014
€14.24
(€0.34 / Piece)
46 Variants
508984
€13.40
(€0.80 / Piece)
26 Variants
041913
€13.91
(€0.33 / Piece)
512491
€13.02
(€1.55 / Piece)
17 Variants
509030
€13.57
(€0.32 / Piece)
6 Variants
041915
€13.69
(€0.81 / Piece)
541305
€14.33
(€0.34 / Piece)
542779
€13.66
(€0.65 / Piece)
2 Variants
View all Upat products
Bonded anchor UKA3 Plus Product variants Product Art-No. Drill diameter Min. drill hole depth Min. effect. anchorage depth Match Sales unit UKA3 Plus M 8 539948 10 80 UKA3 Plus M 10 539949 12 90 80 ASTA M8 10 90 ASTA M10 / IST M8 UKA3 Plus M 12 539950 14 10 110 110 ASTA M12 / IST M10 UKA3 Plus M 14 539951 10 16 120 120 ASTA M14 UKA3 Plus M 16 10 539952 18 125 125 ASTA M16 / IST M12 10 UKA3 Plus M 20/22 539954 24 170 170 ASTA M20/22 10 UKA3 Plus M 24 539955 28 210 210 ASTA M24 / IST M20 5 Load table Permissible loads of a single anchor1) 2) in normal concrete of strength class C20/25. Type Material / surface3) Effective anchoragedepth Minimummember thickness MaximumInstallationtorque Cracked concrete Non-cracked concrete Permissible tension (Nperm) and shear loads (Vperm); minimum spacing Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads (smin) and edge distances (cmin) with reduced loads hef [mm] hmin [mm] Tinst,max [Nm] Nperm4) [kN] Vperm4) [kN] smin4) [mm] cmin4) [mm] Nperm4) [kN] Vperm4) [kN] smin4) [mm] cmin4) [mm] ASTA M8 5.8 80 110 10 - - - - 9 6.3 40 40 ASTA M8 R-70 80 110 10 - - - - 9.6 6 40 40 ASTA M10 5.8 90 120 20 5.05 9.7 45 45 13.8 9.7 45 45 ASTA M10 R-70 90 120 20 5.05 9.2 45 45 14.0 9.2 45 45 ASTA M12 5.8 110 140 40 7.4 14.3 55 55 20.5 14.3 55 55 ASTA M12 R-70 110 140 40 7.4 13.7 55 55 20.6 13.7 55 55 ASTA M16 5.8 125 170 60 11.2 26.9 65 65 27.3 26.9 65 65 ASTA M16 R-70 125 170 60 11.2 25.2 65 65 27.3 25.2 65 65 ASTA M20/22 5.8 170 220 120 19.1 42.3 85 85 43.3 42.3 85 85 ASTA M20/22 R-70 170 220 120 19.1 39.4 85 85 43.3 39.4 85 85 ASTA M24 5.8 210 270 150 28.3 60.5 105 105 59.4 60.5 105 105 ASTA M24 R-70 210 270 150 28.3 56.8 105 105 59.4 56.8 105 105 Chemical fixings For the design the complete current assessment ETA-17/0197 has to be considered. Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. 2) The specified loads are valid for anchorages in dry and damp concrete. For temperatures in the anchoring substrate up to 24 °C (resp. short term up to 40 °C). Drill hole cleaning as per specification in the ETA. The factor ψsus for sustained load was taken into account with 1.0. 3) Further steel grades, versions and technical data see ETA, e.g. for dry internal conditions, galvanised steel (zp/gvz); for damp interiors and for outdoor use, stainless steel (R). 4) In the case of combinations of tension and shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend using our anchor design software DesignFiX. 1) Load table Permissible loads of a single anchor1) 2) in normal concrete of strength class C20/25. For the design the complete current assessment ETA-17/0197 has to be considered. Type Material / surface3) Effective anchoragedepth Minimummember thickness MaximumInstallationtorque Cracked concrete Non-cracked concrete Permissible tension (Nperm) and shear loads (Vperm); minimum spacing Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads (smin) and edge distances (cmin) with reduced loads hef [mm] hmin [mm] Tinst,max [Nm] Nperm4) [kN] Vperm4) [kN] smin4) [mm] cmin4) [mm] Nperm4) [kN] Vperm4) [kN] smin4) [mm] cmin4) [mm] IST M8 5.8 90 120 10 5,4 5.3 55 55 9 5.3 55 55 IST M8 R-70 90 120 10 5,4 5.9 55 55 9.9 5.9 55 55 IST M10 5.8 90 126 20 7,2 8.3 65 65 13.8 8.3 65 65 IST M10 R-70 90 126 20 7,2 9.3 65 65 15.7 9.3 65 65 IST M12 5.8 125 165 40 11,2 12.1 75 75 20.5 12.1 75 75 IST M12 R-70 125 165 40 11,2 13.5 75 75 22.5 13.5 75 75 IST M20 5.8 200 264 120 27,9 35.4 125 125 55,2 35.4 125 125 IST M20 R-70 200 264 120 27,9 39.4 125 125 55,2 39,4 125 125 Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. 2) The specified loads are valid for anchorages in dry and damp concrete. For temperatures in the anchoring substrate up to 24 °C (resp. short term up to 40 °C). Drill hole cleaning as per specification in the ETA. The factor ψsus for sustained load was taken into account with 1.0. 3) Further steel grades, versions and technical data see ETA, e.g. for dry internal conditions, galvanised steel (zp/gvz); for damp interiors and for outdoor use, stainless steel (R). 4) In the case of combinations of tension and shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend using our anchor design software DesignFiX. 1) 57

108 Pages | Valid until 12/2026 | |

PDF Download (55MB)
Save page as PDF
Request quotation
(non-binding)

Choose your language

Legal issues

The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.

Request form for special products

Personal-Quote Personal-Quote

The ToolTeam® Procurement Service

Are you looking for products that are shown in the catalogue but cannot be purchased directly online?
Our procurement service will be pleased to make you a non-binding and individual offer.


Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)