Upat Fastening Technology - Main Catalog Page 49
Commercial customer offer**
Show products
Top sellers from Upat
539948
€5.37
(€0.64 / Piece)
542955
€5.50
539949
€5.42
(€0.65 / Piece)
520256
€8.03
542947
€8.03
(€0.10 / Piece)
539951
€7.98
(€0.95 / Piece)
000856
€12.77
041913
€13.91
(€0.33 / Piece)
041915
€13.69
(€0.81 / Piece)
541305
€14.33
(€0.34 / Piece)
View all Upat products
Injection mortar UPM33 Load table Permissible loads of a single anchor1) 2) in normal concrete of strength class C20/25. For the design the complete current assessment ETA-10/0171 has to be considered. Screw Material3) Effective anchoragedepth Minimummember thickness MaximumInstallationtorque hef [mm] hmin [mm] Tinst,max [Nm] Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads Nperm4) [kN] Vperm4) [kN] smin4) [mm] cmin4) [mm] 55 IST M8 5.8 90 120 10 9,0 5.3 55 IST M8 8.8 90 120 10 13.8 8.3 55 55 IST M8 R-70 90 120 10 9.9 5.9 55 55 IST M10 5.8 90 130 20 13.8 8.3 65 65 IST M10 8.8 90 130 20 16.7 13.3 65 65 IST M10 R-70 90 130 20 15.7 9.3 65 65 IST M12 5.8 125 170 40 20.5 12.1 75 75 IST M12 8.8 125 170 40 26.6 19.3 75 75 IST M12 R-70 125 170 40 22.5 13.5 75 75 IST M16 5.8 160 210 80 37.6 22.4 95 95 IST M16 8.8 160 210 80 39.5 30.9 95 95 IST M16 R-70 160 210 80 39.5 25.1 95 95 IST M20 5.8 200 260 120 55.2 35.4 125 125 IST M20 8.8 200 260 120 55.2 42.9 125 125 IST M20 R-70 200 260 120 55.2 39.4 125 125 Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. The specified loads are valid for anchorages in dry and damp concrete. For temperatures in the anchoring substrate up to 50 °C (resp. short term up to 80 °C). Drill hole cleaning as per specification in the ETA. The factor Ψsus for sustained load was taken into account with 1.0. 3) Further steel grades, versions and technical data see ETA, e.g. for dry internal conditions, galvanised steel (zp/gvz); for damp interiors and for outdoor use, stainless steel (R). 4) In the case of combinations of tension and shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend using our anchor design software DesignFiX. 1) 2) Chemical fixings Type 49
108 Pages | Valid until 12/2026 | Previous page | Next page
Choose your language
Legal issues
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)
