Upat Fastening Technology - Main Catalog Page 43
Commercial customer offer**
Show products
Top sellers from Upat
539948
€5.37
(€0.64 / Piece)
542955
€5.50
539949
€5.42
(€0.65 / Piece)
520256
€8.03
542947
€8.03
(€0.10 / Piece)
539951
€7.98
(€0.95 / Piece)
000856
€12.77
041913
€13.91
(€0.33 / Piece)
041915
€13.69
(€0.81 / Piece)
541305
€14.33
(€0.34 / Piece)
View all Upat products
Injection mortar UPM44 Load table Permissible loads of a single anchor1) 2) in normal concrete of strength class C20/25. For the design the complete current assessment ETA-02/0022 has to be considered. Material / surface3) Effective anchoragedepth Minimummember thickness MaximumInstallationtorque Cracked concrete Non-cracked concrete Permissible tension (Nperm) and shear loads (Vperm); minimum Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads spacing (smin) and edge distances (cmin) with reduced loads hef [mm] hmin [mm] Tinst,max [Nm] Nperm4) [kN] Vperm4) [kN] smin4) [mm] cmin4) [mm] Nperm4) [kN] Vperm4) [kN] smin4) [mm] UPM-A/ASTA M8 5.8 60 100 10 3.9 6.3 40 40 7.9 6.3 40 cmin4) [mm] 40 UPM-A/ASTA M8 5.8 80 110 10 5.3 6.3 40 40 9 6.3 40 40 UPM-A/ASTA M8 5.8 160 190 10 9 6.3 40 40 9 6.3 40 40 UPM-A/ASTA M8 R-70 60 100 10 3.9 6 40 40 7.9 6 40 40 UPM-A/ASTA M8 R-70 80 110 10 5.3 6 40 40 9.9 6 40 40 UPM-A/ASTA M8 R-70 160 190 10 9.9 6 40 40 9.9 6 40 40 UPM-A/ASTA M10 5.8 60 100 20 5.4 9.7 45 45 9.9 9.7 45 45 UPM-A/ASTA M10 5.8 90 120 20 8.1 9.7 45 45 13.8 9.7 45 45 UPM-A/ASTA M10 5.8 200 230 20 13.8 9.7 45 45 13.8 9.7 45 45 UPM-A/ASTA M10 R-70 60 100 20 5.4 9.2 45 45 9.9 9.2 45 45 UPM-A/ASTA M10 R-70 90 120 20 8.1 9.2 45 45 14.8 9.2 45 45 UPM-A/ASTA M10 R-70 200 230 20 15.7 9.2 45 45 15.7 9.2 45 45 UPM-A/ASTA M12 5.8 70 100 40 7.5 14.3 55 55 13.7 14.3 55 55 UPM-A/ASTA M12 5.8 110 140 40 11.8 14.3 55 55 20.5 14.3 55 55 UPM-A/ASTA M12 5.8 240 270 40 20.5 14.3 55 55 20.5 14.3 55 55 UPM-A/ASTA M12 R-70 70 100 40 7.5 13.7 55 55 13.7 13.7 55 55 UPM-A/ASTA M12 R-70 110 140 40 11.8 13.7 55 55 21.7 13.7 55 55 UPM-A/ASTA M12 R-70 240 270 40 22.5 13.7 55 55 22.5 13.7 55 55 UPM-A/ASTA M16 5.8 80 120 60 11.5 23 65 65 16.8 26.9 65 65 UPM-A/ASTA M16 5.8 125 170 60 18 26.9 65 65 29.9 26.9 65 65 UPM-A/ASTA M16 5.8 320 360 60 37.6 26.9 65 65 37.6 26.9 65 65 UPM-A/ASTA M16 R-70 80 120 60 11.5 23 65 65 16.8 25.2 65 65 UPM-A/ASTA M16 R-70 125 170 60 18 25.2 65 65 29.9 25.2 65 65 UPM-A/ASTA M16 R-70 320 360 60 42 25.2 65 65 42 25.2 65 65 UPM-A/ASTA M20 5.8 90 140 120 14 28 85 85 20 40 85 85 UPM-A/ASTA M20 5.8 170 220 120 28 42.3 85 85 48.3 42.3 85 85 UPM-A/ASTA M20 5.8 400 450 120 58.6 42.3 85 85 58.6 42.3 85 85 UPM-A/ASTA M20 R-70 90 140 120 14 28 85 85 20 39.4 85 85 UPM-A/ASTA M20 R-70 170 220 120 28 39.4 85 85 48.3 39.4 85 85 UPM-A/ASTA M20 R-70 400 450 120 65.7 39.4 85 85 65.7 39.4 85 85 UPM-A/ASTA M24 5.8 96 160 150 15.4 30.8 105 105 22 44.1 105 105 UPM-A/ASTA M24 5.8 210 270 150 33.9 60.6 105 105 67.9 60.9 105 105 UPM-A/ASTA M24 5.8 480 540 150 77.6 60.6 105 105 84.3 60.9 105 105 UPM-A/ASTA M24 R-70 96 160 150 15.4 30.8 105 105 22 44.1 105 105 UPM-A/ASTA M24 R-70 210 270 150 33.9 56.8 105 105 67.9 56.8 105 105 UPM-A/ASTA M24 R-70 480 540 150 77.6 56.8 105 105 94.3 56.8 105 105 UPM-A/ASTA M30 5.8 120 190 300 21.5 43.1 140 140 30.8 61.6 140 140 UPM-A/ASTA M30 5.8 280 350 300 50,3 96 140 140 106.8 96 140 140 UPM-A/ASTA M30 5.8 600 670 300 107.7 96 140 140 133.8 96 140 140 UPM-A/ASTA M30 R-70 120 190 300 21.5 43.1 140 140 30.8 61.6 140 140 UPM-A/ASTA M30 R-70 280 350 300 50.3 90.2 140 140 106.8 90.2 140 140 UPM-A/ASTA M30 R-70 600 670 300 107.7 90.2 140 140 150.1 90.2 140 140 Chemical fixings Type Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. 1) The specified loads are valid for anchorages in dry and damp concrete. For temperatures in the anchoring substrate up to 50 °C (resp. short term up to 80 °C). Drill hole cleaning as per specification in the ETA. The factor Ψsus for sustained load was taken into account with 1.0. 2) Further steel grades, versions and technical data see ETA, e.g. for dry internal conditions, galvanised steel (zp/gvz); for damp interiors and for outdoor use, stainless steel (R). 3) In the case of combinations of tension and shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend using our anchor design software DesignFiX. 4) 43
108 Pages | Valid until 12/2026 | Previous page | Next page
Choose your language
Legal issues
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)
