Bolt anchor MAX Load table Permissible loads of a single anchor1) in normal concrete of strength class C20/25 For the design the complete current assessment ETA-10/0170 has to be considered. MAX 10 MAX 12 MAX 16 MAX 20 Non-cracked concrete Permissible Tension (Nperm), Shear loads (Vperm), minimum spacing Permissible Tension (Nperm), Shear loads (Vperm), minimum spacing Minimummember thickness Installationtorque hef hmin Tinst Nperm3) Vperm3) smin3) cmin3) Nperm3) Vperm3) smin3) cmin3) [mm] [mm] [Nm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm] zp 35 80 20 2.6 7.8 35 40 4.9 7.8 40 40 zp 45 90 20 3.8 7.8 35 40 6.7 7.8 40 40 R 35 80 20 2.6 9.5 35 40 4.9 9.6 40 40 40 surface2) MAX 8 Cracked concrete Effective anchoragedepth Material / (smin) and edge distances (cmin) (smin) and edge distances (cmin) R 45 90 20 3.8 9.6 35 40 6.7 9.6 40 zp 40 90 45 4.1 12.2 40 45 5.9 12.2 40 45 zp 60 110 45 6.2 12.2 40 45 9.5 12.2 40 45 R 40 90 45 4.1 13.3 40 45 5.9 15.1 40 45 R 60 110 45 6.2 15.1 40 45 9.5 15.1 40 45 zp 50 100 60 5.8 17.5 50 55 8.3 17.5 50 55 zp 70 120 60 9.5 17.5 50 55 10.5 17.5 50 55 R 50 100 60 5.8 18.6 50 55 8.3 21.9 50 55 R 70 120 60 9.5 21.9 50 55 10.5 21.9 50 55 zp 65 140 110 8.6 31.4 60 65 12.3 31.4 65 65 zp 85 140 110 12.9 31.4 60 65 18.4 31.4 65 65 R 65 140 110 8.6 25.8 60 65 12.3 36.8 65 65 R 85 140 110 12.9 38.6 60 65 18.4 39.9 65 65 zp 100 170 200 16.4 42.6 95 85 23.4 46.5 95 95 R 100 170 200 16.4 42.6 95 85 23.4 60.7 95 95 Steel fixings Type Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. 1) Further steel grades, versions and technical data see ETA, e.g. for dry internal conditions, galvanised steel zp; for damp interior stainless steel R and exterior conditions, e.g. material 1.4362, 1.4401. 2) In the case of combinations of tensile and shear loads, bending moments and reduced edge and axial spacings (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend to use our anchor design software DesignFiX. 3) 13
108 Pages | Valid until 12/2026 | Previous page | Next page
Choose your language
Legal issues
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)