Rothoblaas - Soundproofing Solutions Page 92
Commercial customer offer**Top sellers from RothoBlaas Deutschland
XYLOFON 50 CODES AND DIMENSIONS CODE Shore XYL50080 XYL50090 XYL50100 XYL50120 XYL50140 XYL50160 50 B L s B L s [mm] [m] [mm] [in] [ft] [in] 80 90 100 120 140 160 3,66 3,66 3,66 3,66 3,66 3,66 6,0 6,0 6,0 6,0 6,0 6,0 3 1/8 3 1/2 4 4 3/4 5 1/2 6 1/4 12 12 12 12 12 12 1/4 1/4 1/4 1/4 1/4 1/4 pcs 1 1 1 1 1 1 TABLE OF USE(1) CODE XYL50080 XYL50090 XYL50100 XYL50120 XYL50140 XYL50160 load for acoustic optimisation(2) [kN/m] [lbf/ft] min max 17,6 12981 54,4 40123 19,8 14604 61,2 45139 22 16226 68 50154 26,4 19472 81.6 60185 30,8 22717 95,2 70216 35,2 25962 108,8 80247 compression for acoustic optimisation(2) [N/mm2] [psi] min max 0,22 31.9 0,68 98.6 reduction [mm] [mil] min max 0,07 3 0,6 24 compressive stress at 3 mm (ultimate limit state) [N/mm2] [psi] 8,59 1246 (1) The load ranges reported here are optimised with respect to the acoustic and static behaviour of the material in compression. However, it is possible to use profiles with loads outside the indicated range if the resonance frequency of the system and the deformation of the profile at the ultimate limit state are assessed. See the manual for transmissibility and attenuation graphs. (2)Resilient profiles must be properly loaded in order to isolate medium/low frequency vibrations transmitted structurally. It is advisable to assess the load according to the operating conditions because the building must be acoustically insulated under everyday load conditions (add the value of the permanent load to 50% of the characteristic value of the incidental load Q linear = qgk + 0.5 qvk). TECHNICAL DATA Properties standard value USC conversion Acoustic improvement Δl,ij(3) Compressive modulus Ec Dynamic elastic modulus E’5Hz -E’50Hz Damping factor tanδ5Hz - tanδ50Hz Compression set c.s. Compressive stress at 1 mm (1/32 in)strain σ 1mm Compressive stress at 2 mm (1/16 in) strain σ 2mm Compressive stress at 3 mm (1/8 in) strain σ3mm Dynamic stiffness s’(4) Max processing temperature (TGA) Reaction to fire Water absorption after 48h ISO 10848 ISO 844 ISO 4664-1 ISO 4664-1 ISO 1856 ISO 844 ISO 844 ISO 844 ISO 9052 EN 13501-1 ISO 62 10,6 dB 7,11 MPa 3,93 MPa - 4,36 MPa 0,173 - 0,225 1,25% 1,11 N/mm2 3,5 N/mm2 8,59 N/mm2 1455 MN/m3 200 °C class E < 1% 1031 psi 1610 psi - 1958 psi 161 psi 508 psi 1246 psi 392 °F - (3)Δ = K l,ij ij,with - Kij,without. See the manual for more information on configuration. (4)The standard requires for measurement with loads between 0.4 and 4 kPa and not with the product operating load. PERFORMANCE Acoustic improvement tested: Δl,ij(3) : 10,6 dB Maximum applicable load (deformation 3 mm): 8,59 N/mm2 Acoustic load: from 0,22 to 0,68 N/mm2 94 | XYLOFON | STRUCTURAL NOISE
162 Pages | Valid until 04/2024 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
