Rothoblaas - Plates and Connectors Page 561

Commercial customer offer**
Page 560Rothoblaas - Plates and Connectors Page 561
Show products
search
keyboard_arrow_up
/ 580

Products from catalog page

-31% RothoBlaas Deutschland RothoBlaas HELMET ECO PAN
PAN
€22.82
33,19 € MSRP
3 Variants
-31% RothoBlaas Deutschland RothoBlaas HEARING PROTECTION - NOISE REDUCTION 29DB HEAD
HEAD
€22.65
32,98 € MSRP
View all RothoBlaas Deutschland products
STRUCTURAL CHARACTERISTIC VALUES Valid for a single threaded rod (INA or MGS) when installed with IR in C20/25 grade concrete with a thin reinforcing layer, considering spacing, edge-distance, and base-concrete thickness as non-limiting parameters� UNCRACKED CONCRETE TENSION rod IR-M6 IR-M8 IR-M10 IR-M12 IR-M16 IR-M20 NRk,c | NRk,s [kN] hef,min [mm] 5.8 steel 60 70 80 90 96 120 10,0 17,0 29,0 42,0 46,3 64,7 8.8 steel γM γM 16,0 27,0 35,2 42,0 46,3 64,7 1,5(1) 1,5(2) 1,5(1) 1,5(2) SHEAR rod IR-M6 IR-M8 IR-M10 IR-M12 IR-M16 IR-M20 VRk,s(1) [kN] hef,min [mm] 5.8 steel 60 70 80 90 96 120 5,0 9,0 15,0 21,0 38,0 61,0 γMs 8.8 steel γMs 1,25 8,0 14,0 23,0 34,0 60,0 98,0 1,25 CRACKED CONCRETE TENSION rod NRk,s | NRk,c [kN] hef,min IR-M6 IR-M8 IR-M10 IR-M12 IR-M16 IR-M20 [mm] 5.8 steel 60 70 80 90 96 120 10,0 17,0 24,6 29,4 32,4 45,3 hef,min [mm] 5.8 steel 60 70 80 90 96 120 5,0 9,0 15,0 21,0 38,0 61,0 NRk,s [kN] hef γM [mm] 5.8 steel 1,5(1) ≥ 70 ≥ 80 ≥ 100 ≥ 120 ≥ 180 ≥ 240 10,0 17,0 29,0 42,0 76,0 123,0 1,5(2) NRk,s [kN] hef γM [mm] 8.8 steel γM 1,5(1) ≥ 70 ≥ 90 ≥ 130 ≥ 160 ≥ 240 ≥ 330 16,0 27,0 46,0 67,0 121,0 196,0 1,5(1) SHEAR rod IR-M6 IR-M8 IR-M10 IR-M12 IR-M16 IR-M20 VRk,s | VRk,cp [kN] 8.8 steel γMs 1,25 8,0 14,0 23,0 34,0 64,8 90,5 γM 1,25(1) 1,5(5) incremental factor for NRk,p(3) Ψc C25/30 C30/37 C40/50 C50/60 1,02 1,04 1,07 1,10 NOTES GENERAL PRINCIPLES (1) Steel failure mode� (2) Concrete cone failure method� • The values are according to EN 1992-4:2018 with a factor αsus=0�6 and in accordance with ETA-23/0419� (3) Tensile-strength increment factor (excluding steel failure) for both cracked and uncracked concrete� (4) Pull-out and concrete cone failure� (5) Pry-out failure in the concrete� In the presence of flooded holes, the factors γM in the case of both the concrete cone pull-out and failure and concrete cone formation are both equal to 1�8� Component A classification: Skin Irrit� 2; Eye Irrit� 2; Skin Sens� 1; Aquatic Chronic 2� Component B classification: Acute Tox� 4; Skin Corr� 1A; Eye Dam� 1; Skin Sens� 1 • The design values are obtained from the characteristic values as follows: Rd = Rk/γM� Coefficients γM are listed in the table in accordance with the failure characteristics and product certificates� • For the calculation of anchors with reduced spacing, or too close to the edge, please refer to ETA� Similarly, in case of fastening on concrete-supports with a better-grade, limited thickness or a thick reinforcing layer please see ETA� • For the design of anchors subjected to seismic loading refer to ETA and to EN 1992-4:2018� • For specifications of the diameters covered by the various certifications (cracked concrete, uncracked concrete, seismic applications), please refer to ETA� ANCHORS FOR CONCRETE | EPO-FIX | 561

580 Pages | Valid until 12/2026 | |

PDF Download (261MB)
Save page as PDF
Request quotation
(non-binding)

Choose your language

Legal issues

The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.

Request form for special products

Personal-Quote Personal-Quote

The ToolTeam® Procurement Service

Are you looking for products that are shown in the catalogue but cannot be purchased directly online?
Our procurement service will be pleased to make you a non-binding and individual offer.


Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)