Rothoblaas - Plates and Connectors Page 14
Commercial customer offer**
Show products
Top sellers from RothoBlaas Deutschland
BAND3580
€20.99
(€31.23 / Metre)
30,50 € MSRP
WALKBASE
€30.21
40,50 € MSRP
AOS01
€26.21
RG020
€22.82
30,41 € MSRP
RBGWEIGHT
€22.44
29,91 € MSRP
RIG3
€29.12
42,60 € MSRP
PATROLTERM
€23.91
RBGBASEVD
€26.09
34,92 € MSRP
LADPLATEIT
€28.31
37,90 € MSRP
FASTOVAL2
€25.42
37,10 € MSRP
HEAD
€22.65
32,98 € MSRP
EAR26
€60.24
88,99 € MSRP
ROPBRA2
€333.94
505,00 € MSRP
RAILSLIDE
€416.30
HANGTEMP
€397.27
550,00 € MSRP
PATROLMED
€44.62
VERTOP17A4
€656.22
SLIDE2
€168.91
PATROLANG
€119.54
HANGWALL
€136.85
188,99 € MSRP
PLANK
€251.39
380,00 € MSRP
POLE
€361.64
547,02 € MSRP
LINO15
€104.36
(€8.28 / Metre)
156,01 € MSRP
FRAMENET
€520.08
721,00 € MSRP
PLATROPE
€282.44
427,02 € MSRP
View all RothoBlaas Deutschland products
FIRE AND METAL CONNECTIONS MATERIAL BEHAVIOUR Timber structures properly designed ensure high performance also under fire circumstances� TIMBER Timber is a combustible material that burns at a predictable rate: when exposed to fire, a portion of the cross section is lost through charring and pyrolysis while the inner, residual section retains its mechanical characteristics (strength and stiffness)� One-dimensional design (effective) charring rate for solid timber and glulam ß0≈0,65 mm/min METAL Metals, primarily steel used in the construction of timber buildings, are noncombustible materials that are highly heat conductive and can cause structural failures during fire events if not detailed and protected correctly� When exposed to fire and high temperatures, the mechanical properties (strength and stiffness) of metal rapidly decrease� This aspect, if not considered, may cause an unintended collapse of the connection. charred thickness zone charred heat affected (pyrolysis) zone residual cross section connector FIRE STRIPE GRAPHITE initial cross section Looking at the cross-section of a timber element after it has been exposed to fire, three layers can be identified: • a charred zone corresponding to the layer of wood completely affected by the combustion process; • a heat affected (pyrolysis) zone that has not yet been charred but has undergone temperature increases above 100°C, which is assumed to have zero residual resistance; • a residual section that retains its initial strength and stiffness properties� By positioning the connector within the residual section, the fire performance required by the design can be achieved� Installation requirements and installation tolerances can lead to a gap between the timber elements� Inside this gap, profiles(FIRE STRIPE GRAPHITE) can be inserted,which, expanding through the heat of the fire, seal the gap and insulate the connector� FIRE DESIGN The design of a connection has as its starting point the verification at room temperature against ultimate limit states (ULS)� It is good practice to design the connection for a work rate lower than the unit for which the design strength is greater than the acting load� This over-resistance of the connection at room temperature is reflected as a favourable effect for verification under fire conditions� Under fire conditions, the stress is 30-50% of the load at room temperature (coefficient ηfi according to EN 1995-1-2:2005)� room temperature Strength fire conditions Strength Rd,ULS ≥ Ed,ULS Rd,fi ≥ Ed,fi Rd,ULS - E d,ULS Ed,ULS Rd,ULS - Rd,fi Ed,ULS - Ed,fi Rd,ULS E d,ULS Rd,ULS - Rd,fi Drop in strength from ambient temperature to fire conditions Rd,ULS E d,ULS Rd,fi E d,fi ≥ Rd,fi Rd,ULS - E d,ULS + Over-resistance at room temperature (ultimate limit states) design strength at room temperature (ultimate limit states) design stress at room temperature design strength under fire conditions design stress under fire conditions 14 | FIRE AND METAL CONNECTIONS | JOINTS FOR BEAM E d,fi E d,ULS - E d,fi Stress drop in the event of fire Ed,fi
580 Pages | Valid until 12/2026 | Previous page | Next page
Choose your language
Legal issues
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)
