Riegler Main Catalog Compressed Air Technology and Pneumatics Page 934

Commercial customer offer**
Riegler Main Catalog Compressed Air Technology and Pneumatics Page 934Page 935
Show products
search
keyboard_arrow_up
/ 944

Products from catalog page

View all Riegler products
INFORMATION / TABLES Compressed air piping system Important installation instructions Only now should the mounting of the vertical wall brackets and the fastening of the compressed air tapping points (Air distributor socket product no.114026, 114027, 114028) be carried out. If the compressed air piping system plans for vertical stubs along a wall, it is recommended to first attach the wall brackets only on the horizontally running pipes and then apply the installation with pressure. 800 mm 400 mm 800 mm 800 mm 800 mm 400 mm 400 mm 400 mm Phase 2: Fastening the line that has pressure applied Phase 1: System without pressure Laying a pipe around columns or obstacles requires that an appropriate distance between the wall and the connector is accounted for. This can be carried out with the installation of an expansion loop as illustrated below. Also a minimum distance of min. 10 cm must be guaranteed between the connector and wall bracket (pipe clamp). 400 mm 400 mm Columns smaller than 1 m Columns larger than 1 m Expansion loop If the piping is planned over greater distances, it is recommended to plan for an expansion loop every 25 meters, (as shown in the drawing to the right). Basically outlet pipes should be designed with a so-called water separator (gooseneck). We recommend here our product no. 114065. Through the user friendly design of the compressed air piping system it is possible to carry out installation and removal without any type of tools. Along with a considerable time savings, this also has a cost savings of up to 50%. In order to guarantee a smooth installation, observe the following points: „ The pipe clamps must be mounted so that the pipe still has sufficient play to shift due to longitudinal expansion „ Another important point to observe is that no burr is on the ends of the pipe in order to prevent damage to the “O” rings of the connectors when plugging together. „ Basically we recommend providing the pipes with a chamfer, in order to reduce the plugging force. „ So that an optimum pipe cut (90 °) is achieved, this should fundamentally be done with our pipe cutter, product 114078. „ To prevent pressure losses in the system, always make sure to push the pipes to the stop in the connector (also see the mark on the connector). „ During installation of the compressed air piping system around columns, the longitudinal expansion of the pipes and connectors must also be taken into account. We recommend a wall distance of approx. 30 mm. 934

944 Pages | Valid until 12/2024 | |

PDF Download (121MB)
Save page as PDF
Request quotation
(non-binding)

Choose your language

Legal issues

The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.

Request form for special products

Personal-Quote Personal-Quote

The ToolTeam® Procurement Service

Are you looking for products that are shown in the catalogue but cannot be purchased directly online?
Our procurement service will be pleased to make you a non-binding and individual offer.


Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)