Pneumax - Hauptkatalog Page 483
Commercial customer offer**Top sellers from Pneumax GmbH
Solenoid valves manifold Series 2500 "OPTYMA-F" - Accessories Electric and electro-pneumatic cut off module Usage examples: EXAMPLE 1: Manifold of 12 monostable valves on which you want to interrupt signals 7-8-9-10 Assembly: - 6 monostable valves (not interruptible because before the module), - 1 additional power supply module, - 6 monostable valves. Please note: the first 4 monostable of these are interruptible by the module, while the following 2 will work correctly managed directly by the corresponding command signals. 2 3 4 5 6 7 8 9 10 11 12 EXAMPLE 2: Manifold of 12 monostable valves on which you want to interrupt signals 7-8-9 Assembly: - 6 monostable valves (not interruptible because before the module), - 1 additional power supply module, - 3 monostable valves (interruptible), - 1 closing plate mounted on a monostable base, - 3 monostable valves (work correctly managed directly by the corresponding command signals). 1 2 3 4 5 6 7 8 9 10 11 12 13 Please note: Each additional power supply module interrupts always 4 electrical signals. If you need to interrupt less than 4 signals you can: - assemble the valves to interrupt in the last positions of the manifold, so you don't need to worry about the interrupted exceeding signals; - use a bistable base and mount a monostable valve (for each signal less than the 4 standard); - use a monostable base and mount a closing plate (for each signal less than the 4 standard). E EXAMPLE 3: Manifold of 7 monostable e 3 bistable valves on which you want to interrupt signals 2-3-4-5 and 8-9-10-11. Assembly: - 1 monostable valve (not interruptible because before the module), - 1 additional power supply module, - 6 monostable valves. Please note: the first 4 monostable of these are interruptible by the module, while the following 2 will work correctly managed directly by the corresponding command signals. - 1 additional power supply module, - 3 bistable valves. Please note: the first 2 bistable of these valves are interruptible by the module, while the following will work correctly managed directly by the corresponding command signals. 1 2 3 4 5 6 7 8 9 11 13 10 12 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distributiOn 1 1 | 463
1106 Pages | Valid until 06/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
