HEDI Main catalogue Page 136
Commercial customer offer**
Show products
Top sellers from HEDI
K4503020I2
€425.00
565,50 € MSRP
G7A40NTF
€128.74
G3000
€71.05
90,00 € MSRP
K3000TF
€73.15
92,65 € MSRP
K3D0016T
€87.39
110,75 € MSRP
K7A25QTF560
€97.35
123,40 € MSRP
ML1209FLED
€115.80
145,34 € MSRP
SD3TF
€22.73
AL521LED
€39.75
47,35 € MSRP
K7A50GTF
€110.55
140,16 € MSRP
AL20LED
€97.27
123,24 € MSRP
H150LED
€108.66
137,73 € MSRP
KVM302016
€81.13
102,82 € MSRP
KVW401132N6I
€377.18
501,85 € MSRP
VKD2516U
€87.90
111,39 € MSRP
KVE301132
€123.82
157,02 € MSRP
K7A25NTF
€77.90
98,70 € MSRP
K7A40NTF510
€101.42
128,53 € MSRP
K740NTF510
€131.08
166,21 € MSRP
K740N2TFP
€395.04
525,63 € MSRP
K2S33N2TF
€130.21
165,08 € MSRP
K2Y50NTF
€109.33
138,61 € MSRP
K7B40GTF
€95.25
120,71 € MSRP
K7B40NTF
€87.31
110,63 € MSRP
VKD2516
€83.28
105,50 € MSRP
K7A25QTF
€97.35
123,40 € MSRP
K7A25N2TFC
€125.42
159,03 € MSRP
K7A40QTF560
€126.72
160,71 € MSRP
KVE601016L
€106.09
134,50 € MSRP
K7A25UTF
€89.57
113,49 € MSRP
KVW402016N2IS
€367.98
489,66 € MSRP
K4253020I2
€340.21
452,26 € MSRP
KVW302132N6I
€399.08
531,00 € MSRP
9013
€84.33
106,85 € MSRP
AL50LED
€98.61
125,00 € MSRP
G7A25NTF
€92.39
117,10 € MSRP
G7A25NTF010
€100.83
127,82 € MSRP
View all HEDI products
FAQ Frequently asked questions: Luminaires What should I look for when choosing a luminaire? Nowadays, light is a wide-ranging field that is so large that it is easy to lose track of it all. On these pages we would like to explain some terms to help you decide which is the right lighting product for you. / Beam angle When deciding which luminaire is the right one for your application, the area to be illuminated is an important aspect. The beam angle provides information about the angle at which light is emitted forward by a luminaire. The distance of the luminaire to the illuminating object is also a fundamental factor. For uniform illumination of large areas, wide-beam luminaires with a large beam angle should be used. The half-value angle defines the angle at which a spotlight emits at least half of its maximum luminous intensity. Beam angle / Illuminance (lux) Illuminance defines how much light falls on a point of a surface. Since illuminance depends on room characteristics and the effects of other light sources, such as daylight, a decision should rather focus on luminous flux and beam angle. The standard for determining luminous intensity specifies that a luminaire or light source be tested in a completely darkened room in order to measure its values. / Colour temperature (Kelvin) The light colour describes the colour appearance of the light from a light source and is described by the colour temperature in Kelvin (K). It is a decisive criterion for the choice of a luminaire. The Kelvin value of a light source indicates whether it emits a cool or warm light. The lower the Kelvin value, the more the light tends towards "warm white". If the value is higher, the light appears cooler ("cold white"). At workplaces, the most suitable luminaires are those that promote concentration and resemble "daylight white" or "neutral white". HEDI calls this colour temperature of 6,500 Kelvin "Work White". / Luminous efficacy (lm/W) The ratio between lumens (luminous flux) and watts (power consumption) is called luminous efficacy and best describes energy efficiency. The higher the lumen/watt ratio, the better a light source converts the electrical energy introduced into light. / Luminous flux (lm) Luminous flux is measured in lumens (lm) and describes the light output of a light source independent of the beam angle. This allows conclusions to be drawn about the brightness of a luminaire. The higher the lumen value, the more light a luminaire emits (per time unit). At the time of the light bulb and fluorescent lamps, the unit watt was sufficient as a decision criterion to be able to draw a conclusion about the brightness. At the time: The more watts, the brighter the luminaire. That is no longer true these days. / Colour rendering The colour rendering of a light source characterises the colour effect that its light causes on objects. The colour rendering index (Ra or CRI) indicates how naturally colours are reproduced in the light of a light source. This plays an important role in painting activities, for example. A high colour rendering index of at least 80 should be used for this. The scale goes up to 100. Kelvin scale 136 50°
144 Pages | Valid until 12/2025 | Previous page | Next page
Choose your language
Legal issues
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)
