fischer Rögzítőrendszerek főkatalógusa Page 349
Commercial customer offer**Top sellers from Fischer
Stand-off installation TherMax 8/10 · Frame fixings / Stand-off installation Loads Stand-off installation TherMax 8 and 10 Recommended loads¹) of a single anchor in concrete and masonry. Type TherMax 8 TherMax 10 Supplied type of plug for the anchorage in the base material UX 10 x 60 UX 12 x 70 Recommended tensile loads in the respective base material Nrec²) Concrete³) 4) ≥ C20/25 [kN] 1.00 1.00 Solid brick³)4) ≥ Mz 12 [kN] 0.50 0.70 Perforated sand-lime brick³)4) ≥ KSL 12 [kN] 0.60 0.80 Vertically perforated brick4) ≥ Hlz 12 [kN] 0.20 0.30 Aerated concrete³)4) ≥ AAC 4 [kN] 0.40 0.60 [kN] 0.15 0.20 Recommended shear load Vrec , valid für all above mentioned base materials for the stated insulation thickness External Thermal Insulation Composite System5) ≤ 240 mm ¹) Required safety factors are considered. ²) The drilling method is to be adapted to the building material used. As different joint qualities are possible, the given values only apply for installation in the brick. ³) The given recommended tensile loads apply for fastenings with metric screws. When using chipboard screws with diameter 6.0 mm they have to be reduced to 0.35 kN. 4) The given recommended tensile loads apply for fastenings with metric screws. When using a SX 5-plug chipboard screws with diameter 4.5 - 5.5 mm they have to be reduced to 0.1 kN. 5) Values are valid for an ETICS made from PS- respectively PU-rigid foam panels. Thickness of rendering minimum 6 mm. 5 Loads Stand-off installation TherMax 8 and 10 Recommended shear loads¹) for a single anchor. Type UX 10 + TherMax 8³) UX 12 + TherMax 10³) 0.15 0.20 Recommended shear loads Vrec¹) External thermal insulation composite system²) ≤ 240 mm [kN] ¹) Required safety factors are considered. ²) Values are valid for an ETICS made from PS- respectively PU-rigid foam panels. Thickness of rendering minimum 6 mm. ³) In wood installation without plug. Loads Stand-off installation TherMax 8 and 10 Recommended tensile loads¹) for a single anchor in wood. Type TherMax 8 TherMax 10 Recommended tensile loads in the respective base material Nrec²) Beech ≥ D35 [kN] 1.00³) 1.005) Spruce ≥ C24 [kN] 1.004) 1.005) ¹) Required safety factors are considered. ²) Installation without UX-plug. Edge distances and spacings following Eurocode 5. ³) Pre-drilled wood with diameter 6 mm. 4) Pre-drilled wood with diameter 5 mm. 5) Pre-drilled wood with diameter 7 mm. 349
684 Pages | Valid until 12/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
