fischer fixing-systems main-catalogue Page 82
Commercial customer offer**Top sellers from Fischer
Epoxy mortar FIS EM Plus · Chemical fixings Loads Injection system FIS EM Plus with internal threaded anchor RG M I Permissible loads of a single anchor¹) ²) in normal concrete of strength class C20/25. For the design the complete current assessment ETA-17/0979 has to be considered. Screw material³) RG M8 I RG M10 I RG M12 I RG M16 I RG M20 I Minimum member thickness Maximum installationtorque Non-cracked concrete Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads hef hmin Tinst,max Nperm4) Vperm4) smin4) cmin4) Nperm4) Vperm4) smin4) cmin4) [mm] [mm] [Nm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm] 5.8 90 120 10 9.0 5.3 55 55 9.0 5.3 55 55 8.8 90 120 10 11.3 8.3 55 55 13.8 8.3 55 55 R-70 90 120 10 9.9 5.9 55 55 9.9 5.9 55 55 5.8 90 130 20 12.9 8.3 65 65 13.8 8.3 65 65 8.8 90 130 20 12.9 13.3 65 65 20.0 13.3 65 65 R-70 90 130 20 12.9 9.3 65 65 15.7 9.3 65 65 5.8 125 170 40 20.2 12.1 75 75 20.5 12.1 75 75 8.8 125 170 40 20.2 19.3 75 75 32.4 19.3 75 75 R-70 125 170 40 20.2 13.5 75 75 22.5 13.5 75 75 5.8 160 210 80 33.2 22.4 95 95 37.6 22.4 95 95 8.8 160 210 80 33.2 30.9 95 95 47.4 30.9 95 95 R-70 160 210 80 33.2 25.1 95 95 42.0 25.1 95 95 5.8 200 260 120 46.4 35.4 125 125 58.6 35.4 125 125 8.8 200 260 120 46.4 51.4 125 125 66.3 51.4 125 125 R-70 200 260 120 46.4 39.4 125 125 66.7 39.4 125 125 Type 3 Effective anchorage depth Cracked concrete ¹) Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. ²) The specified loads are valid for anchorages in dry and damp concrete. For temperatures in the anchoring substrate up to 50 °C (resp. short term up to 72 °C). Drill hole cleaning as per specification in the ETA. The factor Ψsus for sustained load was taken into account with 1.0. ³) Further steel grades, versions and technical data see ETA, e.g. for dry internal conditions, galvanised steel (gvz); for damp interiors and for outdoor use, stainless steel (R). 4) In the case of combinations of tension and shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend using our anchor design software C-FIX. 82
684 Pages | Valid until 12/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
