Eurotec catalogue fastening technology Page 169

Commercial customer offer**
Page 168Eurotec catalogue fastening technology Page 169
Show products
search
keyboard_arrow_up
/ 444

Products from catalog page

keyboard_arrow_down
  • 8mm (1)
keyboard_arrow_down
  • Aluminium (1)
  • Holz (1)
keyboard_arrow_down
  • Atlas HFS 135 (1)
keyboard_arrow_down
  • 30mm (1)
29660
€43.19
Commercial customer offer**
5 Variants
29676
€88.74
Commercial customer offer**
4 Variants
30036
€218.99
(€13.03 / Piece)
Commercial customer offer**
5 Variants
View all Eurotec products
Timber engineering Technical data Secondary beam Atlas permitted value S min. width [mm] Load F1 min. height [mm] Load F3 Char. value of the load-bearing capacity Rka) [kN] [kN] Load F2 and F4 Char. value of the load-bearing capacity Rka) [kN] Art. no. Type L W 30036 70 70 30 9 50 80 6,80 2,00 4,40 30056 100 100 50 12 80 115 17,40 8,56 10,60 30076 135 135 50 12 80 150 26,70 8,56 15,00 30096 170 170 50 12 80 185 33,40 8,56 16,00 30116 200 200 70 17 100 200 43,00 19,15 22,70 Calculation according to ETA-12/0068. Wood density ρk= 350 kg/m3. All echanical values provided should be viewed as subject to the assumptions that have been made and represent example calculations. All values are calculated minimum values and are subject to typographical and printing errors. a) The characteristic values of the load-bearing capacity Rk should not be treated as equivalent to the max. possible load (the max. force). Characteristic values of the load-bearing capacity Rk should be reduced to dimensioning values Rd with regard to the usage class and class of the load duration: Rd= Rk x kmod / γM. The dimensioning values of the load-bearing capacity Rd should be contrasted with the dimensioning values of the loads (Rd ≥ Ed). Example: Characteristic value for constant load (dead weight) Gk= 2,00 kN and variable load (e. g. snow load) Qk= 3,00 kN. kmod= 0,9. γM= 1,3. → Dimensioning value of the load Ed= 2,00 · 1,35 + 3,00 · 1,5= 7,20 kN. The load-bearing capacity of the joint is therefore considered to have been demonstrated i Rd ≥ Ed. → min Rk= Rd · γM / kmod D.h., i.e. the characteristic minimum value of the load-bearing capacity is calculated based on: min Rk= Rd · γM / kmod → Rk= 7,20 kN · 1,3/0,9= 10,40 kN → comparison with table values. Please note: These are planning aids. Projects must only be calculated by authorised persons. 169

444 Pages | Valid until 12/2024 | |

PDF Download (52MB)
Save page as PDF
Request quotation
(non-binding)

Choose your language

Legal issues

The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.

Request form for special products

Personal-Quote Personal-Quote

The ToolTeam® Procurement Service

Are you looking for products that are shown in the catalogue but cannot be purchased directly online?
Our procurement service will be pleased to make you a non-binding and individual offer.


Please fill in all mandatory fields (underlined in red)
keyboard_arrow_down
Please fill in all mandatory fields (underlined in red)