X-ONE X-PLATE X-SEAL Evolution of the average temperatures recorded in the sample (B) coated (side exposed to fire) The analysis of the results highlights how all of the components in the X-RAD system maintain a T° lower than 500°C for more than 60 min, thus showing excellent fire performance, thanks to the protection offered by the X-SEAL system and by the coated gypsum plasterboard 900 800 Temperature [°C] 700 600 500 400 300 200 100 0 0 10 20 30 40 50 60 70 80 90 Time [min] X-ONE BASESCREW F (7/9) X-ONE CRACK (17/18) X-PLATE FA (2/4/6) X-ONE XPLATE (11/12/13/14) X-PLATE F (3/5) X-ONE BASESCREW FA (8/10) Evolution of the average temperatures recorded in the sample (A) not coated (side exposed to fire) 900 The analysis of the results highlights how most of the components in the X-RAD system (except for the most outer parts of X-ONE) maintain a T° lower than 500°C for at least 30 min, nevertheless showing good fire performance, thanks to the protection offered by the X-SEAL system 800 Temperature [°C] 700 600 500 400 300 200 100 0 0 10 20 40 30 50 60 70 80 90 Time [min] X-PLATE FA (2/4/6) X-ONE XPLATE (11/12/13/14) X-PLATE F (1/3/5) X-ONE BASESCREW FA (8/10) Evolution of the average temperatures recorded in the sample (A) not coated (side not exposed to fire) X-ONE BASESCREW F (7/9) X-ONE CRACK (17/18) Fire performance of the X-RAD system in the test chamber (sample A not coated) 200 180 Temperature [°C] 160 140 120 2BO1 100 2BO2 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 Time [min] Note the significant difference in T° recorded at t = 60 min between the side exposed to fire (T° ≈ 600°C) and the side not exposed (T° ≈ 80°C) t = 24 min t = 101 min X-SEAL 77
84 Stránky | Platí do 04/2024 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.