Pneumax - Hauptkatalog Strana 570
Nabídka komerčních zákazníků **Nejlépe prodávané z Pneumax GmbH
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Solenoid valves manifold Series 3000 M8 analogue outputs modules General - M8 analogue outputs modules M8 analog outputs module converts output data, received from field bus via network node, into analog signal. Each analog output has a resolution of 12 bits, processed from 16 outputs (2 bytes), ignoring 4 less significant bits. During the ordering process, it is necessary to verify that the serial node has enough free outputs. Different models are available: CODE SIGNAL ANALOGUE OUTPUTS MAXIMUM CURRENT ON + 24 VDC RAIL OCCUPIED OUTPUTS 5130.2T.00 VOLTAGE 0-10V 2 1A 32 (4 Byte) 5130.2T.01 VOLTAGE 0-5V 2 1A 32 (4 Byte) 5130.4T.00 VOLTAGE 0-10V 4 2 A (1A for each pair of channel) 64 (8 Byte) 5130.4T.01 VOLTAGE 0-5V 4 2 A (1A for each pair of channel) 64 (8 Byte) 5130.2C.00 CURRENT 4-20mA 2 1A 32 (4 Byte) 5130.2C.01 CURRENT 0-20mA 2 1A 32 (4 Byte) 64 (8 Byte) 64 (8 Byte) 5130.4C.00 CURRENT 4-20mA 4 2 A (1A for each pair of channel) 5130.4C.01 CURRENT 0-20mA 4 2 A (1A for each pair of channel) Power supply of the M8 analog outputs module is provided by 24VDC power input on the serial system (type A, 4 pin M12 power connector, pin 4) or by module 5030.M12, in case it were installed upstream of the outputs module. Modules provide M8 3 pins female connectors and a diagnostic LED for every analog input. The LED indicates signal presence (green) or overload fault (red). Maximum available current for each channel on 24VDC rail (pin 1) is reported in the table. Each module provides an internal resettable fuse, which cuts 24VDC power supply to every M8 connector and turning off green PWR LED when thresholds are exceeded. Outputs of other eventual modules connected to the node continue to operate uninterrupted. By removing the cause of the threshold overrun, green PWR LED gets back in ON status and the module becomes operational again. Scheme / Overall dimensions and I/O layout 90 42 28 M8 3P female connector 4 3 1 42 PIN DESCRIPTION 1 +24 VDC (OUTPUTS) GND 4 OUTPUT 90 3 28 AIR DISTRIBUTION 1 1 | 550 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Ordering code 5130._ _.0_
1106 Stránky | Platí do 06/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
