fischer Rögzítőrendszerek főkatalógusa Strana 157
Nabídka komerčních zákazníků **Nejlépe prodávané z Fischer
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Bez dopravy
Highbond anchor dynamic FHB dyn · Chemical fixings Loads Highbond anchor dynamic FHB dyn Design values for cyclic fatigue loading¹) of a single anchor normal concrete of strength class C20/25²). For the design the complete current approval Z-21.3-1748 has to be considered. Cracked and non-cracked concrete Material/surface Type FHB dyn 12 x 100 FHB dyn 12 x 100 V FHB dyn 16 x 125 FHB dyn 16 x 125 V Effective anchorage depth Minimum member thickness Installation torque Design values of tension (∆NEd,max) and shear loads (∆VEd,max); minimum spacing (smin) and edge distances (cmin) with reduced loads hef hmin Tinst ∆NEd,max³) ∆VEd,max³)4) smin4) cmin4) [mm] [mm] [Nm] [kN] [kN] [mm] [mm] gvz 100 130 40 14.1 6.7 100 2005) gvz 100 200 40 14.1 6.7 100 1005) HCR / 1.4529 100 130 40 11.3 4.4 100 2005) HCR / 1.4529 100 200 40 11.3 4.4 100 1005) gvz 105 130 40 14.1 9.6 100 2005) gvz 105 200 40 14.1 9.6 100 100 gvz 125 160 60 23.0 11.9 100 2005) gvz 125 250 60 23.0 11.9 100 100 HCR / 1.4529 125 160 60 15.6 11.9 100 2005) HCR / 1.4529 125 250 60 15.6 11.9 100 1005) gvz 130 160 60 23.0 17.0 100 2005) gvz 130 250 60 23.0 17.0 100 100 FHB dyn 20 x 170 gvz 170 220 100 28.4 17.0 80 80 FHB dyn 24 x 220 gvz 220 440 120 28.9 22.2 180 1805) 3 ¹) The design values of the cyclic fatigue loading apply for load cycles ≥ 5 x 106 in accordance with design method I - for unknown static lower load. If the static lower load is known and / or for lower number of load cycles higher load values are possible. The partial safety factors as regulated in the design standard are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x h ef . The given load values apply for anchorages in dry and wet concrete and temperatures in the base material up to 50 °C (resp. short-term up to 80 °C) and drill hole cleaning acc. to approval. ²) For higher concrete strength classes up to C50/60 higher permissible loads may be possible, see approval. The concrete is assumed to be standard-reinforced. ³) In the case of combinations of tensile loads, shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups) the design must be carried out in accordance with the provisions of the complete approval. 4) Valid for pulsating loads. For alternating loads see approval. 5) Without reduction of the tension and shear load. For details see approval. 157
684 Stránky | Platí do 12/2025 | Previous page | Další stránka
Vyberte si jazyk
Legální problémy
Výrobce je výhradně zodpovědný za obsah, cenu a detaily produktů a nabídek uvedených v katalozích. Technické a optické změny výrobce a chyby jsou vyhrazeny.
Formulář žádosti o speciální produkty
Služba nákupu ToolTeam®
Hledáte produkty, které jsou uvedeny v katalogu, ale nelze je zakoupit přímo online?Naše služba nákupu vám ráda zpracuje nezávaznou a individuální nabídku.
