Rothoblaas - Wood screws and connectors Sida 64
Kommersiell Kunderbjudande **Toppförsäljare från RothoBlaas Deutschland
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
STATIC VALUES | HARDWOOD CHARACTERISTIC VALUES EN 1995:2014 SHEAR geometry timber-to-timber panel-to-timber(1) TENSION thin steel-timber plate(2) thick steel-timber plate(3) thread withdrawal(4) head pull-through (5) A L b d1 A RV,k RV,k Rax,k Rhead,k [kN] [kN] [kN] [kN] 5,33 6,80 4,15 5,67 8,16 4,15 6,01 9,52 4,15 6,35 10,88 4,15 6 80 50 30 3,21 6 100 60 40 3,61 6 120 70 50 3,61 6 140 80 60 3,61 1,71 1,71 1,71 1,71 4,61 4,95 5,14 6 160 90 70 3,61 6,69 12,24 4,15 8 120 70 50 5,35 2,39 7,31 9,02 12,69 5,20 8 140 80 60 5,43 2,39 7,76 9,47 14,50 5,20 8 160 90 70 5,43 8 180 100 80 5,43 8 200 100 100 5,43 8 220 100 120 5,43 8 240 100 140 5,43 1,71 4,27 2,39 2,39 2,39 2,39 2,39 5,14 8,21 8,27 8,27 8,27 SPLATE = 8 mm 9 RV,k [kN] SPLATE = 4 mm 7 RV,k [kN] SPLATE = 6 mm b SPLATE = 3 mm L SPAN = 12 mm d1 [mm] [mm] [mm] [mm] [mm] SPAN = 15 mm d1 eq. 8,27 9,92 16,32 5,20 10,38 18,13 5,20 10,38 18,13 5,20 10,38 18,13 5,20 10,38 18,13 5,20 NOTES: GENERAL PRINCIPLES: (1) The characteristic shear resistances are calculated considering an OSB3 or • Characteristic values comply with the EN 1995:2014 standard in accordance with ETA-11/0030. OSB4 panel, as per EN 300, or a particle board panel, as per EN 312, with thickness SPAN. (2) The shear resistance characteristics are calculated considering the case of a thin plate (SPLATE ≤ 0,5 d1). (3) The shear resistance characteristics are calculated considering the case of a thick plate (SPLATE ≥ d1). (4) The axial thread withdrawal resistance was calculated considering a 90° angle between the grain and the connector and for a fixing length of b. (5) The axial resistance to head pull-through was calculated using timber ele- • Design values can be obtained from characteristic values as follows: Rd = Rk kmod γM The coefficients γM and kmod should be taken according to the current regulations used for the calculation. ments. • For the mechanical resistance values and the geometry of the screws, reference was made to ETA-11/0030. In the case of steel-to-timber connections, generally the steel tensile strength is binding with respect to head separation or pull-through. • For the calculation process a mass density equal to ρk = 550 kg/m3 has been considered for hardwood (oak) elements. • Values were calculated considering the threaded part as being completely inserted into the wood. • Sizing and verification of the timber elements, panels and steel plates must be done separately. • The connector characteristic strength values are calculated for screws inserted without pre-drilling hole. 64 | HBS HARDWOOD | CARPENTRY
369 Sidor | Gäller till 04/2024 | Previous page | Nästa sida
Välj ditt språk
Juridiska frågor
Tillverkaren ansvarar exklusivt för innehållet, priset och artikeldetaljerna för produkterna och erbjudanden som presenteras i katalogerna. Med förbehåll för tekniska och optiska ändringar av tillverkaren och undantag för fel.
Formulär för specialprodukter
ToolTeam® upphandlingstjänst
Letar du efter produkter som visas i katalogen men inte kan köpas direkt online?Vår upphandlingstjänst kommer med glädje att ge dig ett icke-bindande och individuellt erbjudande.