Rothoblaas - Plates and Connectors Sida 192
Kommersiell Kunderbjudande **Toppförsäljare från RothoBlaas Deutschland
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
TCN200 - TCN240 | PARTIAL FASTENING PATTERNS FOR STRESS F2/3 In the presence of design requirements such as F2/3 stresses of different value or the presence of an intermediate HB layer (levelling mortar, sill or ground) between the wall and the supporting surface, partial fastening patterns can be adopted: FULL PATTERN PATTERN 4 PATTERN 3 PATTERN 2 PATTERN 1 Pattern 2 also applies in case of F4, F5 and F4/5 stresses . MAXIMUM HEIGHT OF THE INTERMEDIATE HB LAYER HB HB configuration on timber nv holes Ø5 [pcs] TCN200 TCN240 CLT C/GL HB max [mm] HB max [mm] nails screws nails screws LBA Ø4 LBS Ø5 LBA Ø4 LBS Ø5 • full pattern 30 36 20 30 32 10 • pattern 4 25 30 30 40 42 20 • pattern 3 20 24 40 50 52 30 • pattern 2 15 18 50 60 62 40 • pattern 1 10 12 60 70 72 50 The height of the H B intermediate layer (levelling mortar, sill or timber platform beam) is determined by taking into account the following regulatory requirements for fastenings on timber: • CLT: minimum distances according to ÖNORM EN 1995-1-1 (Annex K) for nails and ETA-11/0030 for screws . • C/GL: minimum distances for solid timber or glulam with horizontal fibres consistent with EN 1995-1-1 according to ETA considering a timber density of ρk ≤ 420 kg/m3 . TCN200 - TCN240 | VERIFICATION OF ANCHORS FOR CONCRETE FOR F2/3 STRESS Fastening elements to the concrete through anchors shall be verified according to the load acting on the anchor, which can be evaluated through the geometric parameters on the table (e) . Ey calculation eccentricities vary depending on the type of installation selected: 2 internal anchors (IN) or 2 external anchors (OUT) . The anchor group must be verified for: VSd,x = F2/3,d MSd,z = F2/3,d x ey,IN/OUT z x F2/3 ey 192 | TITAN N | PANELS AND BUILDING JOINTS y
576 Sidor | Gäller till 04/2024 | Previous page | Nästa sida
Välj ditt språk
Juridiska frågor
Tillverkaren ansvarar exklusivt för innehållet, priset och artikeldetaljerna för produkterna och erbjudanden som presenteras i katalogerna. Med förbehåll för tekniska och optiska ändringar av tillverkaren och undantag för fel.
Formulär för specialprodukter
ToolTeam® upphandlingstjänst
Letar du efter produkter som visas i katalogen men inte kan köpas direkt online?Vår upphandlingstjänst kommer med glädje att ge dig ett icke-bindande och individuellt erbjudande.
