KS Tools special tools for utility tools and transporters Sida 194
Kommersiell Kunderbjudande **Produkter från katalogsidan
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
12V Battery-, Charging- and Starting System Analyzer 12V Battery-, Charging- and Starting System Analyzer with integrated printer 12V / 24V Battery-, Charging- and Starting System Analyzer with integrated printer • Suitable for 12 volt batteries (lead acid, gel, wet cell, MF, VRLA, calcium, AGM and deep cycle batteries) • Menu-driven, intuitive operation • With integrated thermal printer • Automatic control of the entire test procedure through menu navigation • For the quick and simple determination of battery efficiency while taking the temperature compensation into account • Checks the battery condition, charge status, internal resistance, cold start current value • Battery selection takes place quickly and precisely via printing protocol • With verification function for the starter battery, starter and load circuit measurement • Printing protocol supports the argumentation for workshop customers • The connection to the battery takes place via two plastic-coated crocodile pole clamps • Avoidance of an overload of the battery through too long of a measurement time • Illuminated and very easy to read digital display • 0,43 metre long cable allows for flexible work • Includes thermal paper roll • Resistant rubber cup casing • suitable for 12 Volt batteries (lead acid, gel, wet cell, MF, VRLA, EFB, AGM flat, AGM spiral and deep cycle batteries) • Menu-driven, intuitive operation • With integrated thermal printer • Automatic control of the entire test procedure through menu navigation • For the quick and simple determination of battery efficiency while taking the temperature compensation into account • Checks the battery condition, charge status, internal resistance, cold start current value • Battery selection takes place quickly and precisely via printing protocol • With verification function for the starter battery, starter and load circuit measurement • Printing protocol supports the argumentation for workshop customers • The connection to the battery takes place via two plastic-coated crocodile pole clamps • Avoidance of an overload of the battery through too long of a measurement time • Illuminated and very easy to read digital display • 3 metre long cable allows for flexible work • including 3 thermal paper rolls, memory card and USB data cable • In a practical storage case • Suitable for 12 volt batteries (lead acid, gel, wet cell, MF, VRLA, calcium, AGM and deep cycle batteries) • Automatic control of the entire test procedure through menu navigation • For the quick and simple determination of battery efficiency while taking the temperature compensation into account • Checks the battery condition, charge status, internal resistance, cold start current value • With verification function for the starter battery, starter and load circuit measurement • The measurement results are shown via an accurate 5-digit LCD display • In addition, the measurement results are displayed via coloured symbols: OK, charge and poor • The connection to the battery takes place via two plastic-coated crocodile pole clamps • Avoidance of an overload of the battery through too long of a measurement time • Illuminated and very easy to read LCD display • 0,45 metre long cable allows for flexible work • Resistant rubber cup casing Technical data: Work area SAE: 50-1.400 CCA Work area DIN: 50-800 CCA Work area IEC: 50-800 CCA Work area EN: 50-1.400 CCA Work area CCA: 50-1.400 CCA Voltage range: 1,5-17 V Operating temperature: -18°C up to 55°C Display accuracy: +/- 0,5 Megaohm Frequency range: 100 Hz 550.1646 1,5-17 V 550.1647 Technical data: 1,50 Work area SAE: 40-2.000 CCA Work area DIN: 40-2.000 CCA Work area IEC: 40-2.000 CCA Work area EN: 40-2.000 CCA Work area CCA: 40-2.000 CCA Work area CA / MCA: 40-2.000 CCA Work area JIS#: 40-2.000 CCA Voltage range: 9-36 V Operating temperature: +0°C to +55°C Display accuracy: +/- 0,5 Megaohm Frequency range: 100 Hz 550.1649 Technical data: Work area SAE: 100-1.400 CCA Work area DIN: 100-800 CCA Work area IEC: 100-800 CCA Work area EN: 100-1.400 CCA Work area CCA: 100-1.400 CCA Voltage range: 7,6-17 V Operating temperature: -18°C up to 55°C Display accuracy: +/- 0,5 Megaohm Frequency range: 100 550.1645 194 7,6-17 V 1,00 9-36 V 550.1647 750
528 Sidor | Gäller till 07/2024 | Previous page | Nästa sida
Välj ditt språk
Juridiska frågor
Tillverkaren ansvarar exklusivt för innehållet, priset och artikeldetaljerna för produkterna och erbjudanden som presenteras i katalogerna. Med förbehåll för tekniska och optiska ändringar av tillverkaren och undantag för fel.
Formulär för specialprodukter
ToolTeam® upphandlingstjänst
Letar du efter produkter som visas i katalogen men inte kan köpas direkt online?Vår upphandlingstjänst kommer med glädje att ge dig ett icke-bindande och individuellt erbjudande.
