fischer ETICS-Fixings EWI catalogue Sida 20
Kommersiell Kunderbjudande **Toppförsäljare från Fischer
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
LOADS termoz 8 U 3) Highest permissible loads for a single anchor1) 4) for multiple use for non-structural applications. For the design the complete approval ETA-02/0019 has to be considered. Brick raw density min. compressive brick strength fb Concrete and masonry min. min. spacing 2) edge distance 2) smin cmin min. embedment depth hnom Min. member thickness hmin permissible tensile load 3) Nperm [mm] [mm] [kN] [mm] [mm] 100 0,50 ≥ C12/15 ≥ C16/20 100 0,50 70 6) C50/60 100 0,50 Calcium silicate solid bricks, e.g. acc. to DIN V 106:2005-10, EN 771-2:2011, KS 100 0,50 8U ≥ 1,6 12 70 5) 6) Solid Clay bricks e.g. acc. to DIN 105-100:2012-01, EN 771-1:2011, Mz 100 0,50 8U ≥ 1,6 12 70 5) 6) Hollow calcium silicate brick, acc. to DIN V 106:2005-10, EN 771-2:2011, KSL 100 0,25 8U ≥ 1,4 12 70 5) 6) Vertically perforated clay bricks e.g. acc. to DIN 105-100:2012-01, EN 771-1:2011, HLz 100 0,25 8U ≥ 1,2 12 70 5) 7) Solid lightweight concrete block, e.g. acc. to DIN V 18152-100:2005-10 EN 771-3:2011 Vbl 100 0,20 8U ≥ 0,5 4 70 5) 7) Hollow brick light-weight concrete, e.g. acc. to DIN V 18153-100: 2005-10, EN 771-3:2011 Hbl 100 0,13 8U ≥ 0,5 2 70 5) 7) Autoclaved aerated concrete blocks, e.g. AAC acc. to DIN V 4165-100:2005-10, EN 771-4 100 0,17 ≥ 0,35 2 70 7) 8U 100 0,40 ≥ 0,5 4 70 7) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 [kg/dm³] [N/mm²] Concrete acc. EN 206:2013 8U 1) 2) 3) The partial safety factors for material resistance as regulated in the approval as well as a partial safety factor for load actions of F = 1,5 are considered. Minimum possible axial spacings resp. edge distances acc. approval. Plastic anchor for fixing of external thermal insulation composite systems with rendering acc. ETAG 014. Only tensile wind loads are permitted. 4) 5) 6) 7) The given loads are valid for installation and use of fixations in dry masonry for temperatures in the substrate up to +24 °C (resp. short term up to 40 °C). Restrictions concerning the manufacturer and the permissible hole patterns as well as the web thickness see approval. Hammer drilling Rotary drilling Screw fixings termoz 8 U 3 17
71 Sidor | Gäller till 12/2025 | Previous page | Nästa sida
Välj ditt språk
Juridiska frågor
Tillverkaren ansvarar exklusivt för innehållet, priset och artikeldetaljerna för produkterna och erbjudanden som presenteras i katalogerna. Med förbehåll för tekniska och optiska ändringar av tillverkaren och undantag för fel.
Formulär för specialprodukter
ToolTeam® upphandlingstjänst
Letar du efter produkter som visas i katalogen men inte kan köpas direkt online?Vår upphandlingstjänst kommer med glädje att ge dig ett icke-bindande och individuellt erbjudande.
