Eurotec catalogue fastening technology Sida 241
Kommersiell Kunderbjudande **Toppförsäljare från Eurotec
Timber engineering Load direction F2/3 Fixing in the sole plate Timber/Concrete Anchor nails Dimensions [mm] 4 x 40 Quantity (n) Char. Shear carrying capacity [kN] Fixing in the concrete ceiling Joining devices 4 x 50 Angle-bracket screw 4 x 60 5 x 40 5 x 50 34 23,9 28,1 5 x 60 Paneltwistec CH Rock concrete screws Bolt anchor 5 x 120 Ø 12,5 Ø 12 6 2 2 – 20,5 11,6 34 29,1 32,7 34,9 37,2 Steel S250 156 The load-bearing capacities were determined based on ETA-19/0020 Characteristic load-bearing capacity in kN, wood strength class 350 kg/m³ char. Gross density. The minimum distances between the connectors and the edges according to EC5 must be complied with. Boundary bearing force according to EC3: Fb,Rk ø14mm = 93,75 kN Please note: Verify the assumptions made. The stated values, and type and number of joining devices are based on preliminary measurements. Projects are to be dimensioned exclusively by authorised persons in accordance with the State Building Code. As per LBauO, please contact a qualified structural engineer for a paid proof of stability. We will be happy to refer you to someone. Partial utilisation 2 Load direction F2/3 Fixing in the sole plate and solid timber ceiling Steel Joining devices Timber/Timber Anchor nails Dimensions [mm] 4 x 40 Quantity (n) 4 x 50 4 x 60 5 x 40 5 x 50 29 Char. Shear carrying capacity [kN] 19,3 Paneltwistec CH Angle-bracket screw 5 x 60 29 22,8 23,6 26,5 S250 5 x 120 4 28,3 30,1 – 156 Load direction F2/3 Fixing in the sole plate Joining devices Timber/Concrete Anchor nails Dimensions [mm] 4 x 40 Quantity (n) Char. Shear carrying capacity [kN] Fixing in the concrete ceiling 4 x 50 Angle-bracket screw 4 x 60 5 x 40 29 19,3 22,8 5 x 50 5 x 60 29 23,6 26,5 28,3 30,1 Paneltwistec CH Rock concrete screws Bolt anchor 5 x 120 Ø 12,5 Ø 12 4 2 2 – 14,4 11,2 Steel S250 156 The load-bearing capacities were determined based on ETA-19/0020 Characteristic load-bearing capacity in kN, wood strength class 350 kg/m³ char. Gross density. The minimum distances between the connectors and the edges according to EC5 must be complied with. Boundary bearing force according to EC3: Fb,Rk ø14mm = 93,75 kN Please note: Verify the assumptions made. The stated values, and type and number of joining devices are based on preliminary measurements. Projects are to be dimensioned exclusively by authorised persons in accordance with the State Building Code. As per LBauO, please contact a qualified structural engineer for a paid proof of stability. We will be happy to refer you to someone. 241
444 Sidor | Gäller till 12/2024 | Previous page | Nästa sida
Välj ditt språk
Juridiska frågor
Tillverkaren ansvarar exklusivt för innehållet, priset och artikeldetaljerna för produkterna och erbjudanden som presenteras i katalogerna. Med förbehåll för tekniska och optiska ändringar av tillverkaren och undantag för fel.
Formulär för specialprodukter
ToolTeam® upphandlingstjänst
Letar du efter produkter som visas i katalogen men inte kan köpas direkt online?Vår upphandlingstjänst kommer med glädje att ge dig ett icke-bindande och individuellt erbjudande.
