AMF Catalogue ZERO-POINT SYSTEMS Sida 46
Kommersiell Kunderbjudande **Toppförsäljare från AMF Spannsysteme
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
exkl. Frakt
automation solutions of amf No. 6103LA-5 Installation clamping module for automation solutions, screw-in version Pneumatic opening. Pneumatic blow-out. Opening operating pressure: min. 8 bar - max. 12 bar. Retensioning operating pressure (turbo): min. 5 - max. 6 bar Cover and piston hardened. Repetition accuracy < 0,005 mm. With locking control (pneum.), opening control (pneum.) and support control (pneum.). Order no. 561992 Size Pull-in/locking force up to Holding force* [kN] [kN] 1,5 13 KP5 Blow out Weight ● 175 [g] Design: Centric blow-out, support control, opening and locking control. Application: Zero-point clamping system for automation solutions for set-up-time-optimised clamping during cutting and non-cutting machining. Note: Locking control: Dynamic pressure with locked clamping module, flow-through with opened clamping module. Opening control: Dynamic pressure with opened clamping module, flow-through with locked clamping module. The installation clamping module is opened pneumatically and locked mechanically by spring force. To achieve the specified pull-in and locking forces, it must be briefly retensioned pneumatically (turbo) (5). Subsequent uncoupling of the pressure line is possible at any time (module is clamped at normal pressure). The contact surface is the upper surface of the housing. It is recommended to use a pneumatic pressure booster no. 6370ZVL. Matching mounting tool is available under the AMF order no. 564855. The clamping module has five connections: 1 = pneum. Opening 3 = pneum. Blow-out 4 = pneum. Opening control inlet 5 = pneum. Retensioning and venting 8 = pneum. Inlet locking control * Please observe the installation instructions. On request: - Installation drawings Dimensions: Order no. 561992 Size dia. D dia. DN dia. D1 H HA dia. LK T KP5 M45 x 1 15 39 25,8 5,8 36 20 CAD Subject to technical alterations. 46 ZERO-POINT-SYSTEMS ANDREAS MAIER GmbH & Co. KG ∙ Phone: +49 711 5766-196 ∙ Web: www.amf.de
228 Sidor | Gäller till 12/2025 | Previous page | Nästa sida
Välj ditt språk
Juridiska frågor
Tillverkaren ansvarar exklusivt för innehållet, priset och artikeldetaljerna för produkterna och erbjudanden som presenteras i katalogerna. Med förbehåll för tekniska och optiska ändringar av tillverkaren och undantag för fel.
Formulär för specialprodukter
ToolTeam® upphandlingstjänst
Letar du efter produkter som visas i katalogen men inte kan köpas direkt online?Vår upphandlingstjänst kommer med glädje att ge dig ett icke-bindande och individuellt erbjudande.
