TOX product catalogue Página 151
Oferta para clientes comerciais**Vendedores mais populares de TOX-DÜBEL
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
Building materials & Holding values Gypsum plasterboard 12.5 mm 10 kg Gypsum plasterboard 2x 12.5 mm 15 kg Apollo KB Concrete C 20/25 Solid brick MZ 12 Vertically perforated brick ≥ Hlz12 10/100 80 kg 60 kg 30 kg 35 kg 30 kg 10/120 80 kg 60 kg 30 kg 35 kg 30 kg 10 kg 15 kg 10/140 80 kg 60 kg 30 kg 35 kg 30 kg 10 kg 15 kg 10/160 80 kg 60 kg 30 kg 35 kg 30 kg 10 kg 15 kg Bulk density 1 kg/dm³ Hollow brick ≥ Hbl2 Cellular concrete ≥ PB2, PP2 The anchoring depth of the wall plug must be observed Drilling method and drill hole cleaning must be adapted to the building material The recommended loads only apply to installation in the building material, not for installation in joints Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads) Description & Area of Application 3-way split spreader element with metal tip Shaft with rotation locks Wall plug is completely pre-assembled with galvanized hexagonal screw with SW13 driver Processing & Installation In cellular concrete P2 just hammer in without predrilling 1. Drilling Result in concrete 2. Clean drill hole Result in perforated brick 3. Drive in wall plugs Result in cellular concrete After setting the Apollo KB, be sure to tighten the screw – in cellular concrete, optimum holding values after 6 turns of the screw Drill into perforated brick and gypsum plasterboard without hammering in a rotary motion so that the webs in the perforated brick are not broken In concrete and solid masonry through expansion In perforated brick by spreading and tying Behind gypsum plasterboard by tying Through installation Frames In cellular concrete (aerated concrete), a deep-set rear gripping (tying) is created 4. Tighten screw 151
216 Páginas | Válido até 12/2023 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
