Rothoblaas - Plates and Connectors Página 333
Oferta para clientes comerciais**Vendedores mais populares de RothoBlaas Deutschland
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
The X-SEAL system uses the same logic as the X-PLATE plates . Each configuration is characterized and described by: • LEVEL: indicates whether it is base B (BASE), inter-storey M (MID) or T coverage (TOP) level . • NODE: indicates the type of node (X, T, G, J, I, O) . • THICKNESS: indicates the thickness of the panel that can be used . There are three families of standard thickness values: 100 mm - 120 mm - 140 mm . All panel thickness values between 100 mm and 200 mm can be used, combining the basic components for standard thickness values with SPACER elements having thickness values of 5 and 10 mm . THERMO-HYGROMETRIC BEHAVIOUR The X-RAD system thermal analysis is carried out in order to quantify and verify the point-to-point thermal bridge . The most unfavourable conditions in which to concentrate the study and verification are the ground connection of the BASE G element and the node of the wall and floor connection of the roof, TOP G . The study is performed using a FEM - 3D model . The reference stratigraphy considered represents a possible standard situation in current building practice . The image shows the construction panels and the materials considered . The choice of specific materials allows to contextualize the verifications and does not exclude the use of different products . An overview of the study with some of the results obtained is given below . To obtain the full study report or for more information contact the Rothoblaas technical office . B A NODE A | Ground connection coefficient description 1 value X Chi (16 cm) heat flow - 0,330 W/node fRsi (Te = - 5 °C) temperature factor 0,801 7 2 U1 3 9 6 6 4 5 6 8 U2 NODE A | Thermal flow (Chi) insulation wall transmittance value 12 + 5 cm 0,190 W/m2K - 0,380 W/node 16 + 5 cm 0,160 W/m2K - 0,330 W/node 2 24 + 5 cm 0,121 W/m K - 0,260 W/node NODE A | Danger of mould (Tsi) temperature (te) Tsi insulation 12 cm Tsi insulation 16 cm Tsi insulation 24 cm fRsi-average 0,801 0,811 0,824 - 5,0 °C 15,2 °C 15,5 °C 15,8 °C 0,0 °C 16,0 °C 16,2 °C 16,5 °C 5,0 °C 16,8 °C 16,9 °C 17,1 °C 1 . CLT 10 cm 2 . Timber fibre insulation 5 cm 3 . Plasterboard 4 . Timber floor 5 . Concrete screed 6 . Extruded polystyrene XPS 12 cm 7 . Timber fibre insulation 12 cm 8 . Concrete 9 . Ground PANELS AND BUILDING JOINTS | X-RAD | 333
576 Páginas | Válido até 04/2024 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
