Pneumax - Hauptkatalog Página 419
Oferta para clientes comerciais**Vendedores mais populares de Pneumax GmbH
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
Solenoid valves manifold ISO 15407-2 Series 2700 - Serial systems Configurator Manifold Layout configuration INPUT MODULES 32 OUT VERSION C3 = CANopen® 32OUT D3 = DeviceNet 32OUT P3 = PROFIBUS 32OUT ® A3 = EtherCAT 32OUT (5700 Series) I3 = EtherNet / IP 32OUT N3 = PROFINET IO RT 32OUT L3 = Powerlink 32OUT M3 = Modbus/TCP 32OUT V27 __ . __ ... __ MODUL CONFIGURATION Valve type __ __ Sub-base type __ . __ . __ __ __ ... S.V. POWER RIGHT ENDPLATE U0 = Closed U2 = 25 Poles 1 I/O MODULE M8 (Requires 25 poles right endplate) ... . __ . __ __ ACCESSORIES CONFIGURATION E3 = S.V. 2,3W E5 = S.V. 1W . . . SUB-BASE TYPE 1 = Base type 1 for Monostable (1 electrical signal occupied) 2 = Base type 2 for Bistable (2 electrical signals occupied) ACCESSORIES X VALVE TYPE: A = Self-feeding E = External feeding SHORT CODE FUNCTION / CONNECTION : A= 5/2 SOLENOID - SPRING B= 5/2 SOLENOIS - DIFFERENTIAL C= 5/2 SOLENOID - SOLENOID E= 5/3 CC SOLENOID -SOLENOID F= 2x3/2 NC-NC (= 5/3 OC) SOLENOID -SOLENOID G= 2x3/2 NO-NO (= 5/3 PC) SOLENOID -SOLENOID H= 2x3/2 NC-NO SOLENOID -SOLENOID I= 2x3/2 NO-NC SOLENOID -SOLENOID T= FREE VALVE SPACE PLUG = Diaphragm plug on pipe 1 Y = Diaphragm plug on pipe 3 Z = Diaphragm plug on pipe 5 XY = Diaphragm plug on pipe 1 & 3 ZX = Diaphragm plug on pipe 5 & 1 ZY = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5, 1 & 3 NOTE: While configuring the manifold always be careful that the maximum number of electrical signals available is 32. The use of monostable valve mounted on a base type 2 ( 2 electrical signals occupied ) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. If it is necessary to interrupt more than one conduit in the same time then put in line the letters which identifies the position (for exemple : regarding the 3 & 5 conduits, put the Y & Z letters). Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module. Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 399 Air distributiOn A = No module D1= 8 M8 digital inputs module D2= 8 M12 digital inputs module T1= 2 analogue inputs 0-5V module T2= 2 analogue inputs 0-10V module C1= 2 analogue inputs 0-20mA module C2= 2 analogue inputs 4-20mA module P1= 2 Pt100 inputs 2 wires module P2= 2 Pt100 inputs 3 wires module E1= 2 Pt100 inputs 2 wires module extended range E2= 2 Pt100 inputs 3 wires module extended range
1106 Páginas | Válido até 06/2025 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
