Pneumax - Hauptkatalog Página 211
Oferta para clientes comerciais**Vendedores mais populares de Pneumax GmbH
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
Direct operated solenoid valves Series 300 Technical characteristics Electrical Working pressure Orifice size Maximum fluid temperature Maximum ambient temperature Maximum flow rate at 6 bar with ∆p 1 bar Cycles/minute Fluids Lubrication Life Power consumption holding - D.C Power consumption holding - A.C Operating voltage tolerance Response time opening * Response time closing * Insulation of the copper wire Insulation of the coil Connector protection Cable protection 0 - 10 bar 1,3 mm (0,9 mm for 2 W) 50°C 50°C 53 Nl/min (20NI/min. for 2 W) 700 Air-vacuum-inert gases non required 45 to 50 million cycles 5W (2.5 W) low consumption 9 VA (6 VA) low consumption ±10% 8 ms 6 ms H F IP 65 DIN 43650 INDUSTRIAL FORM (*) "Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001, Pneumatic fluid power - Directional control valves - Measurement of shifting time" Maintenance and replacement parts Maintenance practices for these valves are similar to those already detailed for other productsreplacement of the plunger or poppet is not advisable since the new replacement would not provide the best fit with the rest of the already used valve. Special care should be taken that no dirt is accumulated between the working surface of fixed core and the plunger which would result in vibrations and overheating of the solenoid. In the case of microsolenoid it must be assured that the alternate current coil is not charged when the machanical part is not mounted to avoid destruction of the coil. The electrical connections have to be perfect, especially where low currents are used (12-24V). Oxidation of contacts between the connector and the coil can lead to intermittent malfunctions which are difficult to trace. Oxidation of contacts due to humidity or corrosive atmosphere are one of the most common causes of false alarms. Clean the contacts with appropriate spray. Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 191 1 Air distributiOn Pneumatic
1106 Páginas | Válido até 06/2025 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
