HEWI Catalog Hardware Página 265
Oferta para clientes comerciais**Vendedores mais populares de HEWI
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
EN 1906 | Technical information As far as the application of the above European standard is concerned, door lever handles and door knobs on backplates or roses are classified in accordance to the following 8-digit keys: e. g. HEWI H-technology | 8 mm square 111XAH01.130 4 7 - 0 1 5 0 A e. g. HEWI H-technology | 9 mm square 111XAH11.130 4 7 - B1 1 5 0 A e. g. HEWI R-technology | 9 mm square 111R11.230 4 7 - D1 1 5 0 U Specification for tender Key Possible class Class Meaning of the class Category of use 1 1 to 4 1 Medium frequency of use by persons with high incentive to exercise care, small chance of misuse (e.g. internal residential doors) 2 Medium frequency of use by persons with high incentive to exercise care, some chance of misuse (e.g. internal office doors) 3 High frequency of use by the public or others with little incentive to exercise care and high chance of misuse (e.g. public office doors) 4 High frequency of use on doors subject to frequent violent use or damage Durability 2 6 to 7 6 100.000 test cycles 7 200.000 test cycles Door weight 3 irrelevant – No classification specified Fire resistance 4 0, A, B, C or D 0 No performance defined Technical information (e.g. doors in sports stadiums, barracks or public buildings) A Suitable for installation in smoke control doors A1 do., with 200.000 test cycles tested on a test door B Suitable for installation in smoke control and fire doors B1 do., with 200.000 test cycles tested on a test door C Suitable for installation in smoke control and fire doors with backplate and rose requirements C1 do., with 200.000 test cycles tested on a test door D Suitable for installation in smoke control and fire doors with lever handle core requirements D1 do., with 200.000 test cycles tested on a test door Safety 5 0 or 1 0 For normal use 1 Safety requirements Corrosion resistance 6 0 to 5 0 No classification specified 1 Low corrosion resistance (24 h salt spray test) 2 Moderate corrosion resistance (48 h salt spray test) 3 High corrosion resistance (96 h salt spray test) 4 Extremely high corrosion resistance (240 h salt spray test) 5 Extraordinarily high corrosion resistance (480 h salt spray test) 0 Not burglary resistant 1 Low burglary resistance 2 Moderate burglary resistance 3 High theft protective Security (burglary protection) Design type 7 8 0 to 4 A, B or U 4 Extremely high theft protective A With spring assistance B With spring preload U Without spring assistance HEWI Hardware | 263
450 Páginas | Válido até 12/2024 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
