Ganter Norm Standard Parts - Catalogue Página 1622
Oferta para clientes comerciais**Vendedores mais populares de Ganter Norm
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
Function 3.1 GN 774 Breather Caps continued The overpressure inside the container ensures that the air volume flowing in or escaping owing to fluctuations of the oil level is kept to a minimum. This reduces filter fouling and substantially increases the useful filter life, especially in a dusty environment. Also, a container under pressure has a positive effect on the function of the pump and prevents foaming. 3.3 3.9 3.8 3.7 3.6 The valve seal ensures that no oil can spill to the outside, neither by excessive agitation in the tank nor during transport. 3.4 The air filter prevents the oil from being polluted from the outside (dust). The filter is made of PU foam with a filtration of 40 μm. 3.5 This is achieved by combining two valves (non-return / bypass valve). The inlet valve opens at a vacuum of 30 mbar or greater. The second valves opens at an overpressure > 350 / 700 mbar. 3.2 Breather caps GN 774 with double valve are normally used if the oil container is under pressure and if outside air has to flow back in to compensate for the vacuum caused by falling oil level. Pressure curve Δp [mbar] in the container as factor of the air flow rate [l/min.] at a valve opening pressure of 350 or 700 mbar. 3.5 Controlling, Venting, Sealing of Liquids and Gases | Page 1621
2210 Páginas | Válido até 12/2026 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
