fischer fixing-systems main-catalogue Página 537

Oferta para clientes comerciais**
Página 536fischer fixing-systems main-catalogue Página 537
Mostrar produtos
search
keyboard_arrow_up
/ 684

Produtos da página de catálogo

keyboard_arrow_down
  • TX25 (1)
  • TX30 (1)
keyboard_arrow_down
  • 8 mm (2)
keyboard_arrow_down
  • 108 mm (1)
  • 248 mm (1)
keyboard_arrow_down
  • Ja (2)
-41% Fischer Fischer Putzdübel FIF-CS 8/60 534157
534157
50,25 €
excl. o transporte
(0,50 € / Peça)
84,90 € Preço recomendado
7 Variants
-45% Fischer Fischer Putzdübel FIF-CS 8/200 534164
534164
139,79 €
excl. o transporte
(1,40 € / Peça)
252,65 € Preço recomendado
8 Variants
Ver todos os produtos de Fischer
Render fixing FIF-CS 8 · Insulation fixings Loads Render fixing FIF-CS³) Highest permissible loads for a single anchor¹)4) for fixing of external thermal insulation composite systems with rendering. For the design the complete assessment ETA-15/0006 has to be considered. Concrete and masonry5) Type FIF-CS Brick raw density Minimum compressive brick strength Minimum embedment depth Minimum member thickness Permissible tensile load³) Minimum spacing²) Minimum edge distance²) ρ fb hnom [N/mm²] [mm] hmin [mm] Nperm [kg/dm³] [kN] smin [mm] cmin [mm] Concrete acc. to EN 206-1:2000 - C12/15 – C50/60 356) 100 0.40 100 100 Solid clay bricks Mz according to EN 771-1:2011 ≥ 1.8 20 356) 100 0.40 100 100 Vertically perforated clay bricks HLz according to EN 771-1:2011 ≥ 1.0 12 257) 100 0.20 100 100 Lightweight aggregate concrete LAC according to EN 1520:2011 ≥ 0.9 6 356) 100 0.20 100 100 Autoclaved aerated concrete blocks AAC according to EN 771-4:2011 ≥ 0.5 4 357) 100 0.10 100 100 ¹) The partial safety factors for material resistance as regulated in the assessment as well as a partial safety factor for load actions of γL = 1,5 are considered. ²) Possible minimum spacing resp. edge distance according to assessment. ³) Plastic anchor for fixing of external thermal insulation composite systems with rendering according to ETAG014. Only tensile wind loads are permitted. 4) The given loads are valid for installation and use of fixations in dry base material for temperatures in the substrate up to +24 °C (resp. short term up to +40 °C). 5) Restrictions concerning the manufacturer and the permissible hole patterns as well as the web thickness see assessment. 6) Drill method hammer drilling. 7) Rotary drilling. 11 537

684 Páginas | Válido até 12/2025 | |

PDF Download (82MB)
Guardar página como PDF
Pedir oferta
(não vinculativa)

Escolha a sua língua

Questões legais

A oferta destina-se exclusivamente a clientes empresariais, empresas, instituições públicas, comerciantes e freelancers. Todos os preços nos catálogos são exclusivos de IVA, custos de envio e sobretaxas, se aplicável.
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.

Formulário de pedido de produtos especiais

Personal-Quote Personal-Quote

O serviço de aquisições de ToolTeam®

Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?
O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.


Favor preencher todos os campos obrigatórios (sublinhados em vermelho)
keyboard_arrow_down
Favor preencher todos os campos obrigatórios (sublinhados em vermelho)