fischer fixing-systems main-catalogue Página 233
Oferta para clientes comerciais**Vendedores mais populares de Fischer
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
Concrete screw ULTRACUT FBS II 8-14 · High performance steel anchors Loads Concrete screw UltraCut FBS II for temporary fastening Permissible loads of a single anchor¹) in normal concrete of strength class C20/25 to C50/60. For the design the complete current assessment Z-21.8-2049 has to be considered. Cracked and non-cracked concrete Material/ surface FBS II 10 FBS II 12 FBS II 14 Minimum member thickness Maximum installation torque Minimum spacing (smin) and edge distances (cmin) Permissible load Fperm4) hnom hmin Timp, max²) smin cmin³) fc,cube ≥ 10 N/mm² fc,cube ≥ 15 N/mm² fc,cube ≥ 20 N/mm² fc,cube ≥ 25 N/mm² [mm] [mm] [Nm] [mm] [mm] [kN] [kN] [kN] [kN] gvz 50 100 400 200 65 1.9 2.3 2.6 2.9 gvz 65 150 400 300 100 3.6 4.4 5.1 5.6 gvz 55 105 400 210 70 2.2 2.7 3.1 3.5 gvz 65 130 400 260 85 2.9 3.5 4.1 4.5 gvz 85 205 650 410 135 5.8 7.1 8.1 9.1 gvz 60 120 400 240 80 2.8 3.4 3.9 4.4 gvz 75 150 400 300 100 4.0 4.9 5.6 6.1 gvz 100 240 650 480 160 7.6 9.3 10.8 12.0 gvz 65 115 400 230 75 2.3 2.8 3.2 3.6 gvz 85 150 400 300 100 3.6 4.4 5.0 5.6 gvz 115 255 650 510 170 8.9 10.9 12.6 14.0 Type FBS II 8 Screw-in depth 4 ¹) Material safety factor as well as a partial safety factor for load actions of γL = 1.4 is considered. The screw may be used in the concrete member before the characteristic compressive strength fck,cube is reached. In this case, the concrete compressive strength fc,cube must have reached a value of at least 10 N/mm². Only intended for temporary use and one-time screwing into the same drill hole. Conditions for reuse of the screw see, approval. ²) Values for impulse wrenches with tangential impact and automatic stop device. ³) In case of combined action of shear load and installation close to the edge, the edge distance must be ≥ cmin x 1.5. Detail see approval. 4) Values valid for all load directions. 233
684 Páginas | Válido até 12/2025 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.