fischer ETICS-Fixings EWI catalogue Página 25
Oferta para clientes comerciais**Vendedores mais populares de Fischer
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
Screw fixings termoz CS 8 DT 110V The recessed ETICS screw fixing for soft insulating boards Installation of mineral wool insulation boards on concrete Countersunk installation in mineral wool insulation boards BUILDING MATERIALS APPROVALS ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ 3 22 Building material classes A, B, C, D, E Concrete Concrete (weather shell) Building brick Solid sand-lime brick Hollow blocks made from lightweight concrete Vertically perforated brick Perforated sand-lime brick Lightweight aggregate concrete Aerated concrete ADVANTAGES APPLICATIONS FUNCTIONING ▪ Pre-assembled fixing with a 110 mm disc for countersunk mounting. ▪ The compound screw minimises the thermal bridge, thus there are no fixing marks on the façade. ▪ Recessed installation with round cap provides a smooth surface for thinner render layer. ▪ Less drill wear due to minimum installation depth of 35 mm in the substrate. ▪ With flush installation, the disc tapers to a very thin edge, thus providing for optimal retaining of the insulation panel and for application of thin render. ▪ Attachment of ETICS insulating boards on concrete and masonry ▪ Flush installation of insulation materials such as mineral wool panels ▪ Standard embedment depth for all building materials ▪ Fast setting with a standard hammer drill or cordless screwdriver. ▪ Easily recessed installation with the installation tool termoz CS. ▪ The fixing is pushed through the insulation into the drill hole and needs to be screwed tightly. ▪ For recessed installation, the insulation disc has to be covered with a round plug. ▪ The installation is completed when the disc is flush with the insulation panel. ▪ For the length of 250 mm the optional provided bits T25 are needed.
71 Páginas | Válido até 12/2025 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.