Eurotec Catalog Stone System Página 14
Oferta para clientes comerciais**Vendedores mais populares de Eurotec
The specialist for fastening technology The right support spacing for your terrace! Max. support spacing L [mm] for EVO aluminium system profile with adjustable pedestalsa) Profi-Line adjustable pedestals, perm. F = 8,0 kN Payload [kN/m²] Centre distance e [mm] between the profiles 300 350 400 450 500 550 600 800 1000 1000 1000 950 900 850 850 750 d) 1000 950 900 850 850 800 800 700 4,0 c) 900 850 850 800 750 750 700 650 5,0 c) 850 800 800 750 700 700 650 600 2,0 3,0 Max. support spacing L [mm] for EVO Slim aluminium system profile with adjustable pedestalsa) Profi-Line adjustable pedestals, perm. F = 8,0 kN Payload [kN/m²] Centre distance e [mm] between the profilesb) 250 300 350 400 450 500 550 600 2,0 650 600 600 550 550 500 500 500 3,0 d) 550 550 500 500 500 450 450 400 4,0 c) 500 500 450 450 400 400 400 400 5,0 c) 500 450 450 400 400 400 350 350 Indication of max. span at which the profile’s deflection does not exceed L/300. Average board thickness of 25 mm with a specific weight of 7 kN/m³ (larch, pine, Douglas fir). e.g.: spacing between profiles = 550 mm; payload = 2,0 kN/m² max. span of the profile = 600 mm. c) Payloads according to DIN EN 1991-1; roof terraces = 4 kN/m², patios for public use = 5 kN/m². d) Load capacity according to SIA 261 for balconies and roof terraces private use = 3 kN/m² a) b) Max. support spacing L [mm] for Aluminium Deck Support System HKP with adjustable pedestalsa) Bearing type Single-span beam L Twin-span beam L [mm] Single-span cantilever beam L [mm] / Lk [mm] d) Maximum support distances L [mm] with the adjustable pedestals of the PRO-Line series with a HKP support profilea) Payload kN/m² 300 350 400 450 500 550 600 2,0 3000 2750 2750 2500 2500 2500 2500 e) 2750 2500 2500 2250 2250 2250 2000 4,0 c) 2500 2250 2250 2000 2000 2000 2000 5,0 1750 3,0 2250 2000 2000 2000 1750 1750 2,0 3000 3000 3000 3000 3000 2750 2500 3,0 e) 3000 2750 2500 2250 2000 1750 1750 4,0 c) 2500 2250 2000 1750 1500 1250 1250 5,0 c) 2000 1750 1500 1250 1250 1000 1000 c) 2,0 3000 / 1000 2750 / 1000 2750 / 1000 2500 / 1000 2500 / 1000 2000 / 1000 1750 / 1000 3,0 e) 2500 / 1000 2500 / 1000 2500 / 750 2500 / 750 2500 / 750 2000 / 750 1750 / 750 4,0 c) 1750 / 1000 1500 / 750 1500 / 750 1500 / 750 1500 / 750 1500 / 750 1500 / 750 5,0 1500 / 750 1500 / 750 1500 / 750 1500 / 750 1250 / 750 1250 / 500 1250 / 500 c) Max. bearing clearances (L) for bearings with adjustable pedestals of the PRO-Line series with payloads of 2, 3,4 and 5 kN/m², with a mean board thickness of 25 mm and a board weight of 7 kN/m² (larch, pine, Douglas fir). b) If WPC boards are used, the axis clearance e between the profiles must not exceed 400 mm! c) Load capacities according to DIN EN 1991-1; roof terraces = 4 kN/m², decks for public use = 5 kN/m². d) Lifting forces of up to 1 kN can be sustained on support A. e) Load capacity according to SIA 261 for balconies and roof terraces private use = 3 kN/m². a) 123 14
16 Páginas | Válido até 08/2025 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
