DELTAPLUS - Main Catalogue Página 385
Oferta para clientes comerciais**Vendedores mais populares de DELTA PLUS
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
excl. o transporte
Hand protection TECHNICAL INFORMATION THE EUROPEAN STANDARDS GENERAL REQUIREMENTS EN ISO 21420 PERFORMANCE LEVEL 1 2 3 4 The reference standard, cannot be used alone, but only in combination with another standard containing protection performance requirements. • Conform to harmlessness (pH, chrome VI levels, etc…). • Conform to the size charts (see chart on below). • Assess the dexterity, breathability, and comfort. Ȏ&RQIRUPWRWKHODEHOOLQJLQIRUPDWLRQDQGLGHQWLↅFDWLRQLQVWUXFWLRQV SIZES AS PER STANDARD EN ISO 21420 Glove size Palm circumference (mm) INTENSE ACTIVITY SLOW ACTIVITY -10°C ) T < 0°C -30°C < T 0°C ) T < 10°C -15°C < T 5°C < T -30°C < T -10°C < T HEAT AND FIRE RISK (1৳৯৶ Length (mm) AVERAGE ACTIVITY 7KH(1VWDQGDUGVSHFLↅHVWKHWHVWPHWKRGVWKHJHQHUDOUHTXLUHPHQWVWKHWKHUPDO SHUIRUPDQFHDQGWKHODEHOOLQJRIJORYHVDQGFXↂVWRSURWHFWIURPKHDWDQGↅUH 6 152 160 7 178 171 8 203 182 9 229 192 10 254 204 11 279 215 12 304 226 ,WDSSOLHVWRDOOJORYHVZKLFKPXVWSURWHFWKDQGVIURPKHDWDQGRUↆDPHVLQDQ\RQHRU VHYHUDORIWKHIROORZLQJIRUPVↅUHFRQWDFWKHDWFRQYHFWLYHKHDWUDGLDWLQJKHDWVPDOOVSUD\ of molten metal or large spray of melting metal. PERFORMANCE LEVELS 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 STANDARDISED LABELING/IDENTIFICATION (DFKSURWHFWLYHJORYHLVFOHDUO\LGHQWLↅHGE\D6WDQGDUGLVHGODEHOFRQWDLQLQJWKHIROORZLQJ elements: Ȏ2XUEUDQGORJR Ȏ7KHSURGXFWUHIHUHQFHRUWKHWUDGHQDPH Ȏ7KHVL]H Ȏ$QLQIRUPDWLRQWDJLQGLFDWLQJWKDWLQVWUXFWLRQVDUHDYDLODEOHIRUWKHSURGXFW Ȏ7KH6WDQGDUGLVHGSLFWRJUDP V ZLWKWKHLUSHUIRUPDQFHUDWLQJV Ȏ7KHEDWFKQXPEHU LOT and/or GDWHRIPDQXIDFWXUH Ȏ,IDSSOLFDEOHWKHH[SLU\GDWH (1ৰ৵৲৴৯ REQUIREMENTS 1 to 4 5(6,67$1&(72/$5*(0(7/,1* 0(7$/635$< $PRXQWRIVSUD\UHTXLUHGWRFDXVH GDPDJH 5(6,67$1&(7260$//0(/7,1* 0(7$/635$< $PRXQWRIVSUD\UHTXLUHGWRUDLVHWKHJORYHWRD FHUWDLQWHPSHUDWXUH 5(6,67$1&(725$',$7,1*+($7 7LPHUHTXLUHGWRUDLVHWRDJLYHQWHPSHUDWXUHOHYHO 5(6,67$1&(72&219(&7,9(+($7 7LPHGXULQJZKLFKWKHJORYHLVDEOHWRGHOD\WKHWUDQVIHURIWKH KHDWRIDↆDPH ELECTROSTATIC PROPERTIES 5(6,67$1&(72&217$&7+($7 7HPSHUDWXUH ZLWKLQWKHUDQJHRIr&WRr& DWZKLFKWKHSHUVRQZHDULQJ WKHJORYHVZLOOQRWIHHODQ\SDLQ IRUDSHULRGRIDWOHDVWVHFRQGV 6WDQGDUG(1SURYLGHVDGGLWLRQDOUHTXLUHPHQWVIRUSURWHFWLYHJORYHVWKDWDUHZRUQLQ DUHDVZKHUHↆDPPDEOHRUH[SORVLYHDUHDVH[LVWRUPLJKWEHSUHVHQW )XUWKHUHOHFWURVWDWLFSURSHUWLHVFDQEHGHWHUPLQHGWKURXJK(1 VXUIDFHHOHFWURVWDWLF SURSHUWLHV RU(1 FKDUJHGHFD\ EXWFDQQRWEHXVHGIRUHOHFWURVWDWLFGLVVLSDWLYH SURWHFWLYHJORYHV 5(6,67$1&(72)/$00$%,/,7< 7LPHGXULQJZKLFKWKHPDWHULDOUHPDLQVOLJKWHGDQGFRQWLQXHVWREHFRQVXPHGDIWHUWKH LJQLWLRQVRXUFHKDVEHHQHOLPLQDWHG ,IWKHSURGXFWFODLPVↆDPPDELOLW\UHVLVWDQFHWKHSLFWRJUDPZLOOEH ,IWKHSURGXFWGRHVQRWFODLPDQ\UHVLVWDQFHWRↆDPPDELOLW\ RU; the pictogram will be (1৴ৰৰ HEAT AND FIRE RISK 7KH(1VWDQGDUGGHↅQHVWKHUHTXLUHPHQWVDQGWHVWPHWKRGVIRUFROGSURWHFWLRQJORYHV from cold transmitted by convection or conduction down to -30°C (optionally up to -50°C). This cold can be from climatic conditions or industrial activity. The selection process of a cold protection glove must take into account several parameters such as the ambient temperature, the health of the person, the duration of exposure, and the level of activities... PERFORMANCE LEVEL CONTACT TEMPERATURE °C THRESHOLD TIME (second) 1 100° C * 15 s 2 250° C * 15 s 3 350° C * 15 s 4 500° C * 15 s PERFORMANCE LEVELS REQUIREMENTS 1 to 4 1 to 4 1 IMPERMEABILITY TO WATER RESISTANCE TO CONTACT COLD Measurement of the thermal insulation of the palm of a glove with respect to contact with an object of low temperature (1ৰৱ৳৶৶ WELDERS RISK Requirements and test methods for gloves used for manual welding of metals, for cutting and related techniques. Welder gloves are ranked in two types: B when great dexterity is required (e.g.: TIG welding), and A for other welding processes. RESISTANCE TO CONVECTIVE COLD Measurement of the thermal insulation of a glove with respect to an ambient atmosphere.. www.deltaplus.eu 367
408 Páginas | Válido até 07/2023 | Página anterior | Próxima página
Escolha a sua língua
Questões legais
O fabricante é exclusivamente responsável pelo conteúdo, pelo preço e pelos detalhes dos produtos e das ofertas apresentados nos catálogos. Sujeito a alterações técnicas e ópticas por parte do fabricante e com excepção de erros.
Formulário de pedido de produtos especiais
O serviço de aquisições de ToolTeam®
Está à procura de produtos que são mostrados no catálogo mas que não podem ser comprados diretamente online?O nosso serviço de aprovisionamento terá todo o prazer em fazer-lhe uma oferta individual e não vinculativa.
