fischer Installation Systems Main Catalog Strona 429

Oferta dla klientów komercyjnych**
Strona 428fischer Installation Systems Main Catalog Strona 429
Pokaż produkty
search
keyboard_arrow_up
/ 512

Produkty ze strony katalogu

keyboard_arrow_down
  • 78,00 (2)
keyboard_arrow_down
  • Ja (1)
keyboard_arrow_down
  • Ja (1)
keyboard_arrow_down
  • 105,00 (1)
  • 248,00 (1)
-32% Fischer Fischer Hochleistungsmörtel FIS V Plus 825 S 567511
567511
81,80 €
wył. Wysyłkę
119,89 € Sugerowana cena producenta
-29% Fischer Fischer Statikmischer FIS JMR 567522
567522
46,45 €
wył. Wysyłkę
(3,87 € / Sztuka)
65,49 € Sugerowana cena producenta
Zobacz wszystkie produkty Fischer
Injection mortar FIS V Plus Plugs and anchors ■ Loads Injection system FIS V Plus with internal threaded anchor RG M I Permissible loads of a single anchor1) 2) in normal concrete of strength class C20/25. For the design the complete current assessment ETA-20/0603 has to be considered. Non-cracked concrete Screw Material3) Type RG M 8 I RG M 10 I RG M 12 I RG M 16 I RG M 20 I Effective anchorage depth Minimum member thickness Maximum installation torque Permissible tension (Nperm) and shear loads (Vperm); minimum spacing (smin) and edge distances (cmin) with reduced loads hef hmin Tinst, max Nperm4) Vperm4) smin4) cmin4) [mm] [mm] [Nm] [kN] [kN] [mm] [mm] 5.8 90 120 10 9.0 5.3 55 55 8.8 90 120 10 13.8 8.3 55 55 R-70 90 120 10 9.9 5.9 55 55 5.8 90 130 20 13.8 8.3 65 65 8.8 90 130 20 20.0 13.3 65 65 R-70 90 130 20 15.7 9.3 65 65 5.8 125 170 40 20.5 12.1 75 75 8.8 125 170 40 32.0 19.3 75 75 R-70 125 170 40 22.5 13.5 75 75 5.8 160 210 80 37.6 22.4 95 95 8.8 160 210 80 47.4 30.9 95 95 R-70 160 210 80 42.0 25.1 95 95 5.8 200 260 120 58.6 35.4 125 125 8.8 200 260 120 66.3 51.4 125 125 R-70 200 260 120 65.7 39.4 125 125 11 1) Design according to EN 1992-4:2018 (for static resp. quasi-static loads). The partial safety factors for material resistance as regulated in the ETA as well as a partial safety factor for load actions of γL = 1.4 are considered. As a single anchor counts e.g. an anchor with a spacing s ≥ 3 x hef and an edge distance c ≥ 1.5 x hef. Accurate data see ETA. 2) The specified loads are valid for anchorages in dry and damp concrete. For temperatures in the anchoring substrate up to 50 °C (resp. short term up to 80 °C). Drill hole cleaning as per specification in the ETA. The factor Ψsus for sustained load was taken into account with 1.0. 3) Further steel grades, versions and technical data see ETA, e.g. for dry internal conditions, galvanised steel (gvz); for damp interiors and for outdoor use, stainless steel (R). 4) In the case of combinations of tension and shear loads, bending moments with reduced or minimum spacing and edge distances (anchor groups), the design must be carried out in accordance with the provisions of the complete ETA and the provisions of the EN 1992-4:2018. We recommend using our anchor design software C-FIX. 429

512 Strony | Ważny do 12/2026 | |

PDF Download (54MB)
Zapisz stronę jako PDF
Poproś o wycenę
(niewiążąca)

Wybierz swój język

Zagadnienia prawne

Oferta skierowana jest wyłącznie do klientów biznesowych, firm, instytucji publicznych, handlowców i freelancerów. Wszystkie ceny w katalogach nie zawierają podatku VAT, kosztów wysyłki i ewentualnych dopłat.
Producent ponosi wyłączną odpowiedzialność za treść, cenę i szczegóły dotyczące produktów i ofert prezentowanych w katalogach. Z zastrzeżeniem zmian technicznych i optycznych przez producenta oraz błędów.

Formularz zapytania o produkty specjalne

Personal-Quote Personal-Quote

Usługa zaopatrzenia ToolTeam®

Szukasz produktów, które znajdują się w katalogu, ale nie można ich kupić bezpośrednio online?
Nasz dział zaopatrzenia z przyjemnością przedstawi Ci niezobowiązującą, indywidualną ofertę.


Proszę wypełnić wszystkie pola obowiązkowe (podkreślone na czerwono)
keyboard_arrow_down
Proszę wypełnić wszystkie pola obowiązkowe (podkreślone na czerwono)