Pneumax - Hauptkatalog Pagina 508
Commercieel klantenaanbod**Beste verkopers van Pneumax GmbH
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Solenoid valves manifold Series 2500 "OPTYMA-T" ► Solenoid-Solenoid 5/3 2541.53.31.35.V Coding: VOLTAGE Operational characteristics Fluid Filtered air. no lubrication needed, if applied it shall be continuous Working pressure (bar) From vacuum to 10 Pressure range (bar) V -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 600 responce time according to isO 12238, activation time (ms) 15 responce time according to isO 12238, deactivation time (ms) 20 12 = 24 VDC NPN 05 = 24 VAC 3÷7 temperature °C 02 = 24 VDC PNP Weight 132 g SHORT FUNCTION CODE "E" Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 Air distributiOn 1 ► Solenoid-Solenoid 2x3/2 2541.62.F.35.V Coding: FunCtiOn Operational characteristics Fluid 44 = NC-NC (5/3 Open centres) Filtered air. no lubrication needed, if applied it shall be continuous Working pressure (bar) 55 = NO-NO (5/3 Pressured From vacuum to 10 Pressure range (bar) 3÷7 temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) F centres) 45 = NC-NO (normally 700 closed-normally open) responce time according to isO 12238, activation time (ms) 15 54 = NO-NC (normally responce time according to isO 12238, deactivation time (ms) 25 open-normally closed) VOLTAGE Shifting time of pneumatic directional control valves or moving parts, logic devices were measured in accordance to ISO 12238:2001 V 02 = 24 VDC PNP 12 = 24 VDC NPN 05 = 24 VAC Weight 122 g “Example: if inlet pressure is set at 5bar then pilot pressure must be at least Pp=2,5+(0.2*5)=3,5bar” “Example: if inlet pressure is set at 5bar then pilot pressure must be at least Pp=2,5+(0.2*5)=3,5bar” 4 14 5 1 | 488 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 2 1 12 3
1106 Pagina’s | Geldig tot 06/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
