Pneumax - Hauptkatalog Pagina 449
Commercieel klantenaanbod**Beste verkopers van Pneumax GmbH
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Solenoid valves manifold Series 2200 "OPTYMA-S" - Accessories 8 Input/Output Module Please note: Optyma 32-S solenoid valve manifolds manage up to 32 signals. If the manifold uses more than 24 signals the I/O module will manage only the remainder. Connections that are not managing useful signals will remain unconnected. 1 2 3-4 5-6 ... 23-24 19-20 17-18 21-22 25 26 27 28 29 37 poles Connettor Multi-pole 1 connector pin 30 31 32 ... 26-27 22-23 20-21 24-25 28 29 30 31 32 Connettore 37 poli Attention: Signal Not connected GND Connected Through line Connected Multi-pole connector pin Not connected B) Control via fieldbus: With this kind of control the I/O module can only be used as an output. Pin 1 of each connector is not connected. The output voltage will be 0.7V lower than that applied to Pin 4 of the connector. The maximum output current for each output is 100mA. Te correspondence between control byte and each single output depends on how many electrical signals are used by the manifold and by the relative position of the I/O module. 9 1 2 3-4 5-6 7-8 10 11 12 13 Attention: Output only 3 1 Attention: Only one more I/O module can be added. 4 PIN DESCRIPTION 1 NOT CONNECTED 4 SIGNAL 3 GND 14 15 Serial node Outlet Pin 16 Module 1 9 1 2 3-4 5-6 7-8 10 11 12 13 17 18 19 20 21 Attention: Output only Attention: No more additions are possible 15 14 Serial node Outlet Pin 16 22 23 24 Module 1 Module 2 1 2 3-4 5-6 ... 26-27 22-23 20-21 24-25 28 31 29 32 30 Serial node Outlet Pin Not connected Please note: I/O modules don’t allow to connect any additional valves manifold after them. 1 2 3-4 5-6 7-8 9 10 11 12 13 17 18 19 20 21 Attention: Output only Attention: Signal Not connected GND Connected Attention: Output only Attention: No more additions are possible Serial node Outlet Pin Input Module 14 15 16 22 23 24 Module 1 Module 2 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 429 Air distributiOn 1 2 3-4 5-6
1106 Pagina’s | Geldig tot 06/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
