Pneumax - Hauptkatalog Pagina 419
Commercieel klantenaanbod**Beste verkopers van Pneumax GmbH
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Solenoid valves manifold ISO 15407-2 Series 2700 - Serial systems Configurator Manifold Layout configuration INPUT MODULES 32 OUT VERSION C3 = CANopen® 32OUT D3 = DeviceNet 32OUT P3 = PROFIBUS 32OUT ® A3 = EtherCAT 32OUT (5700 Series) I3 = EtherNet / IP 32OUT N3 = PROFINET IO RT 32OUT L3 = Powerlink 32OUT M3 = Modbus/TCP 32OUT V27 __ . __ ... __ MODUL CONFIGURATION Valve type __ __ Sub-base type __ . __ . __ __ __ ... S.V. POWER RIGHT ENDPLATE U0 = Closed U2 = 25 Poles 1 I/O MODULE M8 (Requires 25 poles right endplate) ... . __ . __ __ ACCESSORIES CONFIGURATION E3 = S.V. 2,3W E5 = S.V. 1W . . . SUB-BASE TYPE 1 = Base type 1 for Monostable (1 electrical signal occupied) 2 = Base type 2 for Bistable (2 electrical signals occupied) ACCESSORIES X VALVE TYPE: A = Self-feeding E = External feeding SHORT CODE FUNCTION / CONNECTION : A= 5/2 SOLENOID - SPRING B= 5/2 SOLENOIS - DIFFERENTIAL C= 5/2 SOLENOID - SOLENOID E= 5/3 CC SOLENOID -SOLENOID F= 2x3/2 NC-NC (= 5/3 OC) SOLENOID -SOLENOID G= 2x3/2 NO-NO (= 5/3 PC) SOLENOID -SOLENOID H= 2x3/2 NC-NO SOLENOID -SOLENOID I= 2x3/2 NO-NC SOLENOID -SOLENOID T= FREE VALVE SPACE PLUG = Diaphragm plug on pipe 1 Y = Diaphragm plug on pipe 3 Z = Diaphragm plug on pipe 5 XY = Diaphragm plug on pipe 1 & 3 ZX = Diaphragm plug on pipe 5 & 1 ZY = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5, 1 & 3 NOTE: While configuring the manifold always be careful that the maximum number of electrical signals available is 32. The use of monostable valve mounted on a base type 2 ( 2 electrical signals occupied ) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. If it is necessary to interrupt more than one conduit in the same time then put in line the letters which identifies the position (for exemple : regarding the 3 & 5 conduits, put the Y & Z letters). Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module. Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 399 Air distributiOn A = No module D1= 8 M8 digital inputs module D2= 8 M12 digital inputs module T1= 2 analogue inputs 0-5V module T2= 2 analogue inputs 0-10V module C1= 2 analogue inputs 0-20mA module C2= 2 analogue inputs 4-20mA module P1= 2 Pt100 inputs 2 wires module P2= 2 Pt100 inputs 3 wires module E1= 2 Pt100 inputs 2 wires module extended range E2= 2 Pt100 inputs 3 wires module extended range
1106 Pagina’s | Geldig tot 06/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
