EN ISO 14122-4 MAINTENANCE LADDER FOR MACHINE SYSTEMS · The topmost rung must end at the level of the exit area. · From an access height of 10,000 mm, the ladder must be · · installed with offset. The maximum length of a ladder section must not exceed 6,000 mm. The offsets are to be positioned at equal intervals, but can also be planned at different heights on request or by using the online configurator. Distance of the rung-leading-edge of the ladder must be at least 200 mm, but may be reduced to 150 mm in the event of obstacles (e.g. pipes). Exit: · According to EN ISO 14122-4, the exit point must · · meet the highest safety requirements. The exit must be secured with a self-closing safety gate. The gap between ladder and building must not exceed 75 mm. For a standard wall distance between ladder and building of 210 mm, this 75 mm gap is provided by using an exit step. The exit stile must be connected to a guardrail which is 1,500 mm long on both sides of the exit surface. Our supplied guardrail can also be dispensed with if there is an option of connecting to a guardrail provided by the customer. Fastening: The standard wall mounting has a gap of 210 mm from the stile axis to the building. The distance between the individual fastening points must not exceed 2,000 mm. They should preferably be attached below the rungs. · · Safety cage: · Distance from the lowest safety cage clamp to the floor: 2,200 mm to 3,000 mm. · Safety cage required from a height of 3,000 mm. 10 Continuous fall protection on request
40 Pagina’s | Geldig tot 12/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.