fischer fixing-systems main-catalogue Pagina 644
Commercieel klantenaanbod**Beste verkopers van Fischer
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Basic knowledge of fastening technology Building material – Concrete. The substrate’s quality is crucial when selecting the correct fixing: Concrete A differentiation is made between concrete, masonry and panel building materials. Concrete is made from a mixture of cement, aggregates and water. 16 Concrete’s main properties are: Concrete is mainly split into two categories: · High level of compressive strength, but only low tensile strength (≈ 10 % of the compressive strength). · Inserting individual rebars and or mats will increase tensile strength (steel + concrete = reinforced concrete). · Structure easily reproducible as it is regulated by standards, therefore it is an ideal anchor base. · Standard concrete and lightweight concrete. While standard concrete contains gravel; lightweight concrete contains additives such as pumice, expanded clay or polystyrene® usually with a lower compressive strength or bulk density. This leads to unfavourable conditions for anchor fixings. · The load bearing capacity of heavy duty fixings depends on the concrete’s compressive and tensile strength. This is indicated by the numbers in the abbreviations: e. g. the most commonly used concrete compressive strength is C20/25 with a cube compressive strength of 25 N/mm². Expert tip Standard concrete qualities: C12/15 to C50/60, even higher grades are also available for special applications. The majority of anchors approved for concrete may only be used from concrete quality from C20/25 up to a max. of C50/60. In the past, designations from DIN 1045 were used in Germany: B25 (~ C20/25) to B55 (~ C45/55). C = concrete 20 = compressive strength fck or fck, cyl of a concrete test cylinder (Ø 150 mm, height 300 mm) in N/mm2 25 = compressive strength fck, cube of a concrete test cube (edge length 150 mm) in N/mm2 644 Normal concrete without accelerating additives reaches its nominal strength after 28 days. Only then can the fixing be installed in compliance with the approval /assessment. Fresh concrete: still workable up to approx. one hour after pouring. Green concrete: starts to harden after four hours, no longer workable. New concrete: is hardened after 28 days, however minimum compressive strength not yet reached. Hard concrete: more than 28 days old, nominal strength reached.
684 Pagina’s | Geldig tot 12/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.